Leads field verification, as-built validation, troubleshooting, and rehabilitation supervision for electrical power, protection, and backup systems in a Combined Cycle Gas Turbine (CCGT) power plant. Evaluates out-of-service or faulty electrical equipment, troubleshoots live plant distribution systems, and supports management across critical adjustment scopes, including Emergency Diesel Generator (EDG) integration, High-Speed Bus Transfer (HSBT) systems, MV/LV switchgear, procurement, electrical commissioning, and asset tagging.
Key Responsibilities
- Perform detailed site walkdowns of HV/MV/LV switchgear, generator, step-up and auxiliary transformers, MCCs, busducts, DC/UPS systems, grounding, and cable routing, cross-checking field conditions against Single Line Diagrams (SLDs), schematics, and cable schedules to produce accurate "As-Built" documentation.
- Rapidly diagnose faults and abnormal conditions in normal plant electrical systems, assessing out-of-service transformers, breakers, motors, protection relays, and UPS/battery banks to judge serviceability and define corrective actions.
- Review, verify, and witness testing of Emergency Diesel Generator (EDG) electrical systems, synchronization, load-shedding/auto-transfer schemes, and High-Speed Bus Transfer (HSBT) logic and settings to ensure seamless emergency power changeover.
- Maintains a uniform log of master markup of all “As-Built” records.
- Acts as single point of contact to Electrical related troubleshooting, verification and related markup records.
- Ability to lead other team members in areas of workload balancing, assignment, verification of outputs, mentoring, training.
- Ability to maintain up to date reporting system.
- Ability to devise, coordinate and supervise practical testing schemes to ensure connectivity of electrical equipment with minimal disruptions to the plant and absolute avoidance of shutdowns.
- Define technical scopes, BOQs, and specifications for electrical replacement equipment, switchgear components, cables, and relays, while supporting vendor technical evaluations and factory/site acceptance tests (FAT/SAT).
- Oversee electrical contractors executing cable laying, termination, megohm/hi-pot testing, relay injection testing, and loop checks to ensure compliance with approved ITPs and procedures.
- Audit and install missing physical KKS/equipment tags on electrical panels, breakers, motors, and junction boxes, recording complete nameplate and technical data for SAP/CMMS integration.
- Produce technical evaluation reports, nonconformance notices, punch lists, and turnover packages while coordinating power isolations and interfaces with I&C, Mechanical, and Operations teams.
Qualifications Required:
- Bachelor’s degree in Electrical Engineering (Power Systems focus preferred).
- 7 to 10 years of experience in power plant electrical commissioning, maintenance, testing, or rehabilitation. Having completed at least 1 CCGT power plant is a must.
- Proven expertise in MV/LV switchgear, protection relays, transformers, UPS/DC systems, EDG synchronization, and bus transfer schemes.
- Proficient in interpreting and updating Single Line Diagrams (SLDs), protection coordination studies, and control schematics.
- Experience with KKS asset identification and SAP/CMMS maintenance databases is a plus