Shift Engineer

Sify

Nagli Sabapur

On-site

INR 450,000 - 600,000

Full time

8 days ago
Application generator

An application made for this job — a tailored resume and cover letter that speak straight to the posting.

Get past ATS filters

Job summary

Sify Infinit Spaces Limited is seeking a Shift Engineer for its Noida (Sector 132) DC facility. You will oversee operation and maintenance of critical infrastructure including transformers, RMU, VCB/ACB, D.G.

sets, PDU, battery banks, and UPS, while ensuring 100% uptime. Responsibilities include commissioning, maintenance and troubleshooting of HT/LT systems, HVAC water-cooled equipment, firefighting systems, IBMS, and energy monitoring (PUE/WUE/CUE).

Qualifications

  • Knowledge of operation and maintenance of DC critical equipment (transformers, RMU, VCB/ACB, DG set, PDU, battery banks, UPS).
  • Experience with HT & LT systems commissioning, maintenance and troubleshooting.
  • Understanding of HVAC water-cooled systems, chillers, cooling towers, and AHU/CRAH units.

Responsibilities

  • Operate and maintain DC critical equipment to ensure 100% uptime.
  • Monitor and manage power, cooling, CPM, and safety interlocks.
  • Plan and execute preventive maintenance and root-cause analyses for breakdowns.
  • Coordinate with vendors for fault rectification per SLA and optimize costs.
  • Ensure compliance with ISO 27001/9001/20000 standards and maintain documentation.

Skills

Data center hardware
HT/LT systems
HVAC water cooled
Firefighting system
IBMS system
PUE/WUE/CUE monitoring
Preventive maintenance
Root cause analysis
Vendor management
Safety protocols

Tools

APFC panels
RMU/VCB/ACB

Job description

Sify Infinit Spaces Limited was created as a subsidiary to house all investments into the Data Center space, specifically colocation. As on date, Sify has 12 Data Center locations spread across India and offers approximately 200MW of IT power to the market with 2 more to be ready by the end of the year. The latest iteration of our Data Centers is AI ready, liquid cooled certified for GPX ready workloads. Apart from these, Sify has also built Data Centers for multiple state governments to house and expand their digital ambitions.

To know more, kindly visit us at https://sifyinfinitspaces.com/

Location : Noida (Sector 132)
About the Role : Shift Engineer
Role Objective:
  • Having knowledge about operation and maintenance at data center and its critical equipments such as Transformer DRY & OIL type, RMU, VCB, ACB, D.G Set, PDU, Battery Banks, UPS and all other switchgears etc.
  • Commissioning, maintenance and troubleshooting of HT & LT system, APFC PANELs for power factor correction. Protective Relays likes O/C, E/F, and O/V, U/V with all safety interlocks.
  • Having knowledge in HVAC system water cooled technology of Chiller - 500TR-1000TR, Cooling tower, Primary Pumps, Secondary Pumps & Condenser Pumps, PAC (precision air conditioning), CRAH Units (UP to 50 TR), AHU, FCU, CSU, Air washer, Dehumidifier’s, VRF & split AC Units.
  • Managing & Monitoring Firefighting system –FM200, Novec 1230, Smoke Detectors, Fire Control Panel, RI, handhold fire extinguisher cylinder, Hydrant & Sprinkler system.
  • Monitoring & maintaining IBMS System- Power, Cooling, CPM, WLD, VESDA, Rodent Repellant System, Gas Suppression system, CCTV, ACS (Access Control System), PAS (Public Address System).
  • Plumbing W.T.P. (MGF, ACF, Softeners and R.O. Plant- 2*30 KL), STP.
  • Monitoring & Maintaining of PUE, WUE & CUE.
  • Planning for new equipment’s installation.
  • Overall supervision of Building maintenance work and handling all complaints-related issue.
  • Maintaining all files and formats Daily/Weekly/Monthly/Annually Reports & presenting to management.
  • 100 % preventive maintenance of all engineering equipment’s to minimize breakdowns & reduction in R & M cost & Coordination with vendors to rectify the fault as per SLA.
  • Preparing root cause analysis for regular breakdown.
  • Internal Audit and verification of sites & ensuring that all certificates of compliance are maintained and up to date in accordance with relevant legislation
  • To ensure cost optimization-Track & review monthly cost of operation. Resource optimization.
  • Ensure billable space optimization, Ensure billing accuracy to be achieved to 100%
  • To ensure DC hosting renewals are happening well in time
  • Service Delivery-100% uptime of DC, Uptime and availability of AHU, UPS, Power and Security systems. 100%
  • Service Delivery: customer-100% service availability
  • Transition-New customer provisioning withing project plan-100% (Track OB- Invoice cycle management)
  • Customer relationship-Ensure communication to customer on relevant issues, meeting customers as needed by business & for service delivery . 100%
  • Internal projects-Site specific internal infra new project management,
  • Ensure all PSS and projects plans are being prepared and shared with customer on time .
  • Ensure Customer Audits-Audit compliance are 100% success and meets their requirements
  • Ensure all business teams are getting support-Assist/support business (customer visits & RFP response), Presales and Product team, 100%
  • Process Compliance-Periodic maintenance of DC components as per BCP Ensure updation and maintenance of all records and reports as per process guide lines 100%
  • Ensure timely delivery and sharing of MIS-Monthly ,DCCP with management and review if required by management
  • Ensure SLA Maintenance - Incident & Problem management Ensure calls are getting attended & SLA met Ensuring proactive and timely support to reduce calls month on Month basis (Zero TAC for Sify Infrastructure related problem). 100%
  • Ensure process Upgrade/improvement-Identification of need for process improvement and implementation. Regular process review, act upon internal audit findings.
  • Ensure process Compliance-Adhering to ISO 27001, ISO 9001, ISO 20000 standards, PCIDSS ISO 45K etc
  • Ensure vendor management-Contract utilization & review are being carried out regularly
  • Ensure knowledge enhancement (Technical as well as Soft skill)for self and team members Periodic training within the team. Set directions for training criteria for each associate
  • Mentoring-Periodic team meeting, empower and motivate team.
  • Succession Planning-Succession planning for key associates
  • Employee Development-Certification Self & team members
Get your free, confidential resume review.
or drag and drop your file here.
Similar jobs

Similar jobs worth comparing

Technical Lead - CSM - Shift Engineer
Technical Lead - CSM - Shift Engineer

Vertiv Co • Mumbai

On-site
INR 1,200,000 - 2,400,000
Dc Operations Manager
Dc Operations Manager

Sify • Sector 10

On-site
INR 2,500,000 - 4,000,000
Shift Manager - DC Operations
Shift Manager - DC Operations

Larsen & Toubro-Vyoma • Chennai District

On-site
INR 1,200,000 - 2,200,000
Technical Lead - CSM - Shift Engineer
Technical Lead - CSM - Shift Engineer

Vertiv Energy • Mumbai

On-site
INR 900,000 - 1,500,000
Assistant Manager-Electrical
Assistant Manager-Electrical

Sify • Mumbai, Navi Mumbai

On-site
INR 1,200,000 - 1,800,000
Shift Operations Engineer
Shift Operations Engineer

AdaniConneX • Hyderabad

On-site
INR 420,000 - 660,000
BMS,HVAC,UPS - Executive - ISS Facility Services - Noida/Gurgaon
BMS,HVAC,UPS - Executive - ISS Facility Services - Noida/Gurgaon

ISS India • Dadri, Gurugram District

On-site
INR 1,200,000 - 1,800,000
Senior Engineer HVAC
Senior Engineer HVAC

Sify • Mumbai, Navi Mumbai

On-site
INR 1,000,000 - 1,500,000
ENGINEER TECHNICAL SUPPORT - L1
ENGINEER TECHNICAL SUPPORT - L1

Network Techlab India Limited • Thane

On-site
INR 300,000 - 540,000
Shift Operations Manager
Shift Operations Manager

AdaniConneX • Hyderabad

On-site
INR 1,000,000 - 1,600,000