Shift Lead, Facility Management

Keppel Data Centres

Johor

On-site

MYR 56,000 - 100,000

Full time

10 days ago

A complete application in a minute

Tailored resume and cover letter, ready to send.

Get past ATS filters

Job summary

Keppel Data Centres in Malaysia is seeking a skilled Data Center Technician to monitor and maintain critical electrical and mechanical systems across the facility. You will work on chiller plants, UPS, generators, PDUs, and building management systems to ensure reliability.

The role requires a Diploma in Electrical or Mechanical Engineering and 3–5+ years in data centers or similar critical environments, with strong English and MS Office skills.

Qualifications

  • Diploma in Electrical or Mechanical Engineering is required.
  • 3 to 5+ years of data center or critical environment experience.
  • Experience with electrical and mechanical systems in data centers.
  • Strong command of Microsoft Office Suite and data reporting.

Responsibilities

  • Daily monitoring of mechanical systems including chillers, pumps, AHU/CRAH units, and fire safety systems.
  • Daily monitoring of electrical systems including switch rooms, transformers, UPS, generators.
  • Ensure data hall temperature and humidity are within range.
  • Respond to equipment alarms on site and troubleshoot faults.
  • Escalate/update severity events per process and procedures.
  • Escort vendors to ensure PM activities and service repairs follow safety procedures and PTW/MOP are reviewed.
  • Monthly/weekly energy consumption reporting and data trending.
  • Maintain building lighting and up-to-date as-built drawings and asset inventory.
  • Monitor tickets via portal or email and respond per SLA.
  • Overseas travel for work as required by supervisor.

Skills

English proficiency
Critical environment experience
HVAC systems knowledge
Electrical systems knowledge
Report generation & analytics

Education

Diploma in Electrical or Mechanical Engineering

Tools

MS Office
SharePoint

Job description

Job Description

Job Description

Your Main Duties And Responsibilities Are As Follows
  • Daily monitoring of Mechanical system including but not limited to: chiller cooling system, water pumps, cooling towers, AHU units, CRAH units, FCU units, water leak detection, fire alarm systems, VESDA, smoke detector (raised floor/ceiling), liquid cooling etc.
  • Daily monitoring of Electrical system including but not limited to: HV/LV switch rooms, Transformers, UPS system, Generators, Power Distribution Units, etc.
  • Ensure Data Hall colocation temperature and humidity are within range.
  • Response and attend to equipment alarm on site.
  • Troubleshoot abnormal incident / fault for Mechanical and Electrical equipment.
  • Escalate/update accordingly any severity event occurred according to the process and procedures.
  • Escorting and overseeing vendor to ensure PM activities and service repairs are carried out properly and compliance with all safety procedures as well as utilization of protective equipment. Ensuring all work performed are in adherence to Company policies and contract agreement. Ensure the submitted PTW and MOP are reviewed and approved before the task is carried out.
  • Monthly/Weekly Electrical and Mechanical system consumption report data trending logging and ensuring timely submission of relevant reports on agreed timing such as monthly basis as required under the requirement of our MSA with customer.
  • Maintain lighting in all areas of the building.
  • Assist in maintaining up to date as built drawings, asset and inventory management.
  • Monitor incoming tickets for processing and provide support to clients/users from the ticketing portal or via email and respond based on SLA.
  • Travel overseas for work / assignment as and when necessary or requested by your immediate supervisor / the head of department.
  • Such other duties and responsibilities as may be reasonably requested by your immediate supervisor / the head of department from time to time.

In the event there are substantial changes to the main duties and responsibilities as set out herein (for example, in cases of secondment, transfer or promotion), the Company will communicate such changes to you in writing.

Job Requirements
  • Diploma in Electrical or Mechanical Engineering, Facilities Management, or equivalent field of study required.
  • An excellent understanding and experience of the electrical and mechanical systems used in a data center environment, including: Feeders, Transformers, Generators, Fuel Systems, Switchgear, UPS systems, Battery banks, ATS/STS units, PDU/PMM units, Chillers, Air handling units, Chilled water plant, CRAC units, Fire Alarm systems, and Fire Suppression systems.
  • Experience of complex automatic control equipment, including relay logic, programmable logic controllers (PLC's), building management systems, and their integration with the data center infrastructure.
  • Advanced knowledge of Microsoft Office Suite - Word, Excel, Outlook and Visio required; working knowledge of SharePoint preferred.
  • Proficiency in both written and spoken English.
  • 3 to 5+ years of experience in a data center or other Critical Environment required (preference is given to data center, hospital, pharmaceutical production or power plant experience).
  • Working knowledge of mechanical, electrical, life safety monitoring and control systems typically used in critical environments.
  • Proficient knowledge of HVAC and/or Electrical Systems. Team Lead shall be proficient in both Electrical and Mechanical.
  • Able to work rotating shifts and on weekends/public holidays.
BUSINESS SEGMENT

Connectivity

PLATFORM

Operating Division

Get your free, confidential resume review.

or drag and drop your file here.

Similar jobs

Similar jobs worth comparing

Site Lead, Facility Management
Site Lead, Facility Management

Keppel Data Centres • Johor

On-site
MYR 90,000 - 150,000
Facilities Management Technician
Facilities Management Technician

MTS Global Pte Ltd • Kulai

On-site
MYR 36,000 - 60,000
SME, Electrical
SME, Electrical

Keppel Data Centres • Johor

On-site
MYR 120,000 - 180,000
Facility Manager
Facility Manager

Xircle Talent • Kulai

On-site
MYR 60,000 - 100,000
Shift Facility Engineer
Shift Facility Engineer

JLL • Johor

On-site
MYR 50,000 - 75,000
Data Centre Senior Facility Manager
Data Centre Senior Facility Manager

Jones Lang LaSalle Property Consultants Pte Ltd • Sungai Buloh

On-site
MYR 134,000 - 201,000
Facilities Manager
Facilities Manager

Aolani Cloud • Kuala Lumpur

On-site
MYR 120,000 - 180,000
Critical Facilities Manager
Critical Facilities Manager

Xircle Talent • Iskandar Puteri

On-site
MYR 180,000 - 300,000
Technical Manager
Technical Manager

Xircle Talent • Kulai

On-site
MYR 90,000 - 160,000
SME, Electrical
SME, Electrical

Keppel (Data Centres and Networks Division) • Sedenak

On-site
MYR 67,000 - 112,000