BICSI Installer II

Archetype Infrastructure Solutions

Ashburn (VA)

In loco

USD 60.000 - 80.000

Tempo pieno

14 giorni+
Generatore di candidature

Una candidatura completa in un minuto — curriculum e lettera di presentazione personalizzati, pronti da inviare.

Supera i filtri ATS

Descrizione del lavoro

Archetype Infrastructure Solutions in Ashburn, VA is seeking a BICSI Certified Level II Installer responsible for the installation and testing of structured cabling systems, ensuring high-quality telecommunications in active data centers. The ideal candidate will have at least 3 years of experience, strong knowledge of both copper and fiber optic systems, and the ability to work in team settings.

The role requires a commitment to safety and compliance, along with good communication skills to collaborate effectively with other trades and lead installers.

Competenze

  • 3+ years of experience in structured cabling or low-voltage installations.
  • Strong knowledge of copper and fiber optic systems.
  • Familiarity with NEC, TIA/EIA, and BICSI standards.

Mansioni

  • Install and dress copper and fiber optic cables in racks and cabinets.
  • Perform cable testing and troubleshoot connectivity issues.
  • Label cables and complete installation documentation.

Conoscenze

Structured cabling systems
Cable testing and certification
Blueprint interpretation
Team collaboration

Formazione

BICSI Certified Level II Installer credential

Strumenti

Fluke testers

Descrizione del lavoro

Location: Ashburn, VA

Employment Type: Full‑Time

Reports To: Lead Installer / Project Manager / Site Superintendent

Position Summary

The BICSI Certified Level II Installer is responsible for the installation, termination, testing, and documentation of structured cabling systems in accordance with BICSI standards, TIA/EIA guidelines, and project specifications. This role supports mission‑critical infrastructure by ensuring high‑quality, compliant, and reliable telecommunications systems within active data center environments.

Key Responsibilities
Structured Cabling Installation
  • Install copper and fiber optic cabling systems (backbone and horizontal)
  • Terminate CAT5e, CAT6, CAT6A, and fiber optic cables (single‑mode and multi‑mode)
  • Install pathways including cable trays, conduits, J‑hooks, ladder racks, and raceways
  • Install and dress cables in racks, cabinets, patch panels, and enclosures
Testing & Quality Assurance
  • Perform cable testing and certification using approved test equipment (e.g., Fluke testers)
  • Troubleshoot and resolve connectivity and performance issues
  • Ensure all work meets BICSI, TIA/EIA, NEC, and client standards
  • Maintain clean, organized, and labeled installations
Documentation
  • Accurately label cables, racks, panels, and termination points
  • Complete test results, as‑built drawings, and installation documentation
  • Report progress, issues, and material needs to site leadership
Safety & Compliance
  • Follow all site safety rules, OSHA standards, and company policies
  • Maintain a safe and organized work area at all times
  • Use proper PPE and tools for all tasks
Team Collaboration
  • Work closely with Level I Installers, Lead Installers, and other trades
  • Assist with training and mentoring junior installers as needed
  • Coordinate with site supervision to maintain schedule and quality
Required Qualifications
  • Current BICSI Certified Level II Installer credential
  • 3+ years of experience in structured cabling or low‑voltage installations
  • Strong working knowledge of copper and fiber optic systems
  • Ability to read and interpret blueprints, schematics, and scope documents
  • Experience with cable testing and certification equipment
  • Familiarity with NEC, TIA/EIA, and BICSI standards
Preferred Qualifications
  • Data center or mission‑critical facility experience (strongly preferred in Ashburn market)
  • Experience with fiber splicing and termination
  • OSHA 10 or OSHA 30 certification
  • Manufacturer certifications (CommScope, Panduit, Corning, etc.)
Physical & Work Requirements
  • Ability to lift up to 50 lbs
  • Ability to work on ladders, lifts, and in confined spaces
  • Comfortable working in active data center construction environments
Ottieni la revisione del curriculum gratis e riservata.

o trascina qui il file.

Similar jobs

Offerte di lavoro simili che vale la pena confrontare

BICSI II Cabling Installer - Data Center Specialist
BICSI II Cabling Installer - Data Center Specialist

Archetype Infrastructure Solutions • Ashburn (VA)

In loco
USD 60.000 - 80.000
BICSI-Certified Cabling Installer II — Data Center Focus
BICSI-Certified Cabling Installer II — Data Center Focus

The Archetype Strategy • Ashburn (VA)

In loco
USD 60.000 - 90.000
Infrastructure Technician III
Infrastructure Technician III

Black Box Corporation • Louisiana (MO)

In loco
USD 60.000 - 80.000
Infrastructure Technician II
Infrastructure Technician II

Garmac Limited LLC • Abilene (TX)

In loco
USD 34.000 - 55.000
Cable Technician
Cable Technician

Technical Source • Raleigh (NC)

In loco
USD 30.000 - 39.000
Structured Cabling Technician
Structured Cabling Technician

SuperHero Fire Protection,LLC. • Raleigh (NC)

In loco
USD 42.000 - 64.000
General Foreman
General Foreman

Black Box • Chandler (AR)

In loco
USD 52.000 - 68.000
Structured Cabling Technician II
Structured Cabling Technician II

Equiliem • Rayville (LA)

In loco
USD 38.000 - 52.000
Health insurance
Dental insurance
Vision insurance
+4
Structured Cabling Technician
Structured Cabling Technician

Iesmart Systems, L.L.C. • Spring (TX), Northern (KY)

Ibrido
USD 40.000 - 60.000
Health and Welfare Plan
401(k) Plan with matching Employer Contribution
Paid Vacation and Holidays
Low Voltage Structure Cabling Technician
Low Voltage Structure Cabling Technician

SuperHero Fire Protection, LLC • Winston-Salem (NC)

In loco
USD 52.000 - 75.000