Fire Protection System Engineer

Jones Lang LaSalle Incorporated

Johor Bahru

On-site

MYR 90,000 - 150,000

Full time

6 days ago
Be an early applicant

Get more replies from employers

Send a job-specific resume in minutes.

Job summary

Jones Lang LaSalle Incorporated is seeking a Data Centre Fire Protection System Engineer in Johor Bahru, Malaysia. You will design, implement, and maintain fire protection systems tailored to data center environments to ensure high availability of critical IT infrastructure.

The role covers system design, installation oversight, commissioning, maintenance, and risk assessment, with emphasis on NFPA standards and integration with building management systems.

Qualifications

  • Bachelor's degree in fire protection, mechanical or electrical engineering or related field.
  • Professional certifications such as NICET Fire Alarm Systems, CFPS or PE in fire protection are valued.

Responsibilities

  • Design fire protection strategies for data centers meeting NFPA standards.
  • Oversee installation and commissioning of fire protection systems.
  • Maintain and ensure NFPA compliance and documentation.
  • Monitor systems and respond to incidents, refine emergency procedures.
  • Conduct fire risk assessments and mitigate vulnerabilities in high-density environments.

Skills

Analytical skills
Problem solving
Communication
Change management
On-site readiness

Education

Bachelor's degree in Fire Protection Engineering
CFPS/PE certification preferred

Tools

AutoCAD
Revit

Job description

Data Centre Fire Protection System Engineer Position Overview

A Data Centre Fire Protection System Engineer is responsible for designing, implementing, maintaining, and optimizing fire detection and suppression systems specifically for mission‑critical data center facilities. This role ensures continuous protection of critical IT infrastructure, servers, and telecommunications equipment while maintaining high availability standards.

Key Responsibilities
System Design and Engineering

The engineer develops fire protection strategies tailored to data center environments, including clean agent suppression systems (FM‑200, Novec 1230, Inergen), VESDA (Very Early Smoke Detection Apparatus), and pre‑action sprinkler systems. They create detailed specifications, system layouts, and integration plans that comply with NFPA standards, local fire codes, and insurance requirements while minimizing water damage risks to sensitive equipment.

Installation Oversight and Commissioning

The role involves managing the installation of fire protection systems during new builds or retrofits, coordinating with contractors, MEP teams, and facility managers. The engineer conducts comprehensive commissioning tests, validates system performance against design specifications, and ensures proper integration with building management systems and emergency response protocols.

Maintenance and Compliance

Regular inspection, testing, and maintenance of all fire protection components falls under this position. The engineer ensures compliance with NFPA72, NFPA75, NFPA76, and other relevant standards, maintains detailed documentation of all inspections and tests, and coordinates required annual certifications with authorities having jurisdiction.

System Monitoring and Incident Response

Continuous monitoring of fire alarm panels, suppression system status, and early warning detection devices is essential. The engineer responds to alarms, investigates false activations, and implements corrective actions. They develop and refine emergency response procedures specific to data center operations.

Risk Assessment and Mitigation

Conducting regular fire risk assessments, identifying vulnerabilities in existing protection schemes, and recommending improvements forms a critical part of the role. This includes evaluating hot aisle/cold aisle containment impacts on smoke detection, assessing risks from high‑density computing environments, and planning protection for evolving infrastructure.

Required Qualifications
Technical Education and Certifications

A bachelor's degree in fire protection engineering, mechanical engineering, electrical engineering, or related field is typically required. Professional certifications such as NICET Fire Alarm Systems LevelIII orIV, CFPS (Certified Fire Protection Specialist), or PE license in fire protection engineering are highly valued.

Technical Expertise

Deep knowledge of data center fire protection technologies including gaseous suppression agents, VESDA and air sampling systems, FM‑200/Novec/Inergen system design and hydraulics, and pre‑action sprinkler systems is essential. Understanding of data center infrastructure including cooling systems, power distribution, raised floor environments, and cable management is required. Proficiency with fire alarm control panels, building management systems integration, and AutoCAD or Revit for system design documentation is expected.

Standards and Codes

Comprehensive understanding of NFPA2001 (Clean Agent Systems), NFPA72 (Fire Alarm Code), NFPA75 (IT Equipment Protection), NFPA76 (Telecommunications Facilities), and local fire codes and insurance requirements is mandatory.

Experience Requirements

Typically 3‑5+ years of experience in fire protection system design, installation, or maintenance with specific data centre or mission‑critical facility experience preferred. Project management experience and familiarity with data center tier classifications (Uptime Institute standards) adds significant value.

Essential Skills

Strong analytical and problem‑solving abilities for troubleshooting complex integrated systems are crucial. The engineer must communicate effectively with IT teams, facility managers, contractors, and emergency responders. Attention to detail in documentation, testing procedures, and compliance reporting is essential. The ability to work under pressure during emergency situations while maintaining data center uptime requirements is expected. Understanding of change management processes in live production environments and the ability to plan maintenance windows around critical operations completes the skill set.

Working Conditions

This position often requires 24/7 on‑call availability for emergency response, occasional work during off‑hours for system testing and maintenance in live environments, and regular site visits to multiple data center locations. Physical requirements include the ability to access raised floors, ceiling spaces, and equipment rooms in data center environments.

Location

Location: On‑site –Johor Bahru, Malaysia

Get your free, confidential resume review.
or drag and drop your file here.
Similar jobs

Similar jobs worth comparing

Fire Protection System Engineer (Data Centre)
Fire Protection System Engineer (Data Centre)

Cushman & Wakefield • Johor Bahru

On-site
MYR 60,000 - 90,000
Mechanical Engineer (Fire Protection – Data Center Projects)
Mechanical Engineer (Fire Protection – Data Center Projects)

MERCU JITU ENGINEERING SDN BHD • Selangor

On-site
MYR 60,000 - 90,000
Data Centre Fire Safety Systems Engineer
Data Centre Fire Safety Systems Engineer

Cushman & Wakefield • Johor Bahru

On-site
MYR 60,000 - 90,000
Senior Fire Protection Engineer - Data Center Focus
Senior Fire Protection Engineer - Data Center Focus

DayOne Data Centers Ltd. • Malaysia

On-site
MYR 120,000 - 180,000
Fire Engineer
Fire Engineer

Hirehub Group • Klang City

On-site
MYR 122,000 - 146,000
Fire Engineer | Klang
Fire Engineer | Klang

Hirehub Group • Klang City

On-site
MYR 100,000 - 134,000
On-Site Data Center Fire Protection Engineer
On-Site Data Center Fire Protection Engineer

Jones Lang LaSalle Incorporated • Johor Bahru

On-site
MYR 90,000 - 150,000
Fire Services Engineer
Fire Services Engineer

DayOne Data Centers Ltd. • Malaysia

On-site
MYR 120,000 - 180,000
Fire Protection Mechanical Engineer for Data Center
Fire Protection Mechanical Engineer for Data Center

MERCU JITU ENGINEERING SDN BHD • Selangor

On-site
MYR 60,000 - 90,000
Senior Fire Protection Engineer — Data Center Projects
Senior Fire Protection Engineer — Data Center Projects

Hirehub Group • Klang City

On-site
MYR 100,000 - 134,000