Get a reply from this employer
Your resume and cover letter, tailored to exactly what they’re hiring for.
Swid Process Technologies Pvt. Ltd. in Pune seeks an experienced Electrical/Electronics engineer for solar PV O&M and service. You will diagnose faults, own warranty claims and manage service spares for assigned plants.
The role covers breakdown and preventive maintenance of DC/AC systems, inverters and earth ground, plus RCA reporting, warranty checks and coordination with SCADA data. Travel and site deployment readiness are required.
Source: SWID Interactive Master Role Bank, IV4; revised 15 October 2026. Source workbook supplied on 12 November 2026.
Operations
Head Asset Management
Another Service Engineer or qualified SCADA Engineer for limited electrical/communication scope
Diagnose and restore electrical/mechanical plant faults while also owning warranty claims and service spares for assigned plants/tickets.
1. Review ticket history, drawings, alarms and likely parts before deployment.
2. Conduct breakdown and preventive maintenance for modules, DC/AC systems, inverters, structures, earthing and related equipment within competence.
3. Diagnose safely, isolate equipment, rectify faults, test restoration and explain work to the customer.
4. Prepare service report and RCA, quantify downtime and recommend prevention for repeat issues.
5. Check warranty eligibility; collect serial numbers, photographs, logs and test evidence and raise/follow OEM claims.
6. Maintain assigned critical-spares records, issue/use/return reconciliation and replacement tracking.
7. Coordinate with SCADA Engineer where data/communication and equipment faults overlap.
Maintain and update the Daily Work Report (DWR) every working day with tasks, progress, results, pending actions, blockers and supporting evidence.
1. Review assigned tickets, history, drawings and safety/access requirements.
2. Confirm visit, tools, calibrated instruments, PPE and probable spares.
3. Follow customer permit and isolation/LOTO process on arrival.
4. Diagnose systematically, repair/replace, test and confirm stable generation.
5. Record readings, serials, photographs, used/returned spares and customer acknowledgement.
6. Raise/update warranty claim and OEM follow-up where applicable.
7. Submit service report, RCA, ticket status and DWR within 24 hours.
Update DWR daily in the company-provided software and share with the reporting manager.
This role remains accountable for the outputs listed above even when work is delegated. During absence or vacancy, the named backup may perform essential transactions within documented authority. Technical approvals, commercial commitments, safety waivers and quality acceptance may be exercised only by a competent and authorized person. Handover must include current trackers, pending actions, access credentials under approved custody, documents and due dates.
1. Safe fault diagnosis and restoration
2. Preventive maintenance
3. First-visit resolution and RCA
4. Warranty claim closure
5. Critical spares accountability
6. Customer service records
Daily Work Report completeness and accuracy
1. Normal generation restored across affected equipment within 48 hours | Target: Within 48 elapsed hours of alert/complaint receipt; all affected equipment restored | Review: Per incident
2. Service response within six hours | Target: Within six elapsed hours of receipt | Review: Per incident
3. First-visit resolution and repeat-fault prevention | Target: First-visit resolution >=90%; repeat faults <=3% | Review: Monthly
4. Service report and root-cause analysis | Target: Within 24 hours | Review: Per ticket
5. Warranty-claim submission | Target: Within 2 working days | Review: Per failure
6. Spare reconciliation | Target: 100% | Review: Per visit/monthly
7. DWR updation and accuracy | Target: 100% of working days with a complete, accurate DWR | Review: Daily
1. Items completed within the specified deadline / items due in the review period x 100; use timestamped records.
2. Items completed within the specified deadline / items due in the review period x 100; use timestamped records.
3. First-visit resolutions / visits x 100; repeat faults / resolved faults x 100.
4. Reports issued correctly by the approved due time ÷ reports due × 100.
5. Compare warranty-claim submission with the stated target using the approved register and period; retain item-level supporting evidence.
6. Items completed within the specified deadline / items due in the review period x 100; use timestamped records.
7. Working days with a complete and accurate DWR / working days due x 100; verify work evidence, progress, blockers and manager review.
1. Normal generation restored across affected equipment within 48 hours: 40%
2. Service response within six hours: 20%
3. First-visit resolution and repeat-fault prevention: 15%
4. Service report and root-cause analysis: 10%
5. Warranty-claim submission: 10%
6. Spare reconciliation: 5%
7. DWR updation and accuracy: 0%
Review performance monthly using the specified KPI periods and evidence. Weights total 100% and express relative importance. Assess each KPI against its stated target and approved weight. Non-Sales roles have no exceeds-expectations band. Mandatory requirements remain applicable regardless of weight. Where no activity is due, record not applicable with the reason; do not record zero or invent achievement.
Respond within six elapsed hours of alert/complaint receipt. Within 48 elapsed hours restore normal generation across every affected item of equipment; partial restoration does not meet the target. Retain ticket, response, restoration and customer-update evidence.
DWR is mandatory for every role: update every working day. It is monitored as a separate compliance requirement with no additional weight; existing KPI weights remain unchanged.
100%
Approved targets retained; hierarchy revised
Normal generation restored across affected equipment within 48 hours
Department: Operations
Target: Within 48 elapsed hours of alert/complaint receipt; all affected equipment restored
Review: Per incident
Measurement method: Items completed within the specified deadline / items due in the review period x 100; use timestamped records.
Weight: 40%
Status: Approved targets retained; hierarchy revised
Service response within six hours
Department: Operations
Target: Within six elapsed hours of receipt
Review: Per incident
Measurement method: Items completed within the specified deadline / items due in the review period x 100; use timestamped records.
Weight: 20%
Status: Approved targets retained; hierarchy revised
First-visit resolution and repeat-fault prevention
Department: Operations
Target: First-visit resolution >=90%; repeat faults <=3%
Review: Monthly
Measurement method: First-visit resolutions / visits x 100; repeat faults / resolved faults x 100.
Weight: 15%
Status: Approved targets retained; hierarchy revised
Service report and root-cause analysis
Department: Operations
Target: Within 24 hours
Review: Per ticket
Measurement method: Reports issued correctly by the approved due time ÷ reports due × 100.
Weight: 10%
Status: Approved targets retained; hierarchy revised
Warranty-claim submission
Department: Operations
Target: Within 2 working days
Review: Per failure
Measurement method: Compare warranty-claim submission with the stated target using the approved register and period; retain item-level supporting evidence.
Weight: 10%
Status: Approved targets retained; hierarchy revised
Spare reconciliation
Department: Operations
Target: 100%
Review: Per visit/monthly
Measurement method: Items completed within the specified deadline / items due in the review period x 100; use timestamped records.
Weight: 5%
Status: Approved targets retained; hierarchy revised
DWR updation and accuracy
Department: Operations
Target: 100% of working days with a complete, accurate DWR
Review: Daily
Measurement method: Working days with a complete and accurate DWR / working days due x 100; verify work evidence, progress, blockers and manager review.
Weight: 0%
Status: Mandatory requirement; no separate weight
1. Electrical/Electronics engineering degree/diploma; valid electrical competency where required.
2. 3+ years in solar PV O&M/service or industrial electrical maintenance.
3. Fault-finding capability for DC/AC systems, inverters, earthing, protection and mechanical issues.
4. Test-instrument, LOTO, permit and work-at-height competence.
5. Warranty documentation, spare control, RCA and customer communication skills.
6. Travel, emergency call-out and site deployment readiness.