IUOE Plant Operator, 2nd Class

University of Rochester

City of Rochester (NY)

In loco

USD 44.000 - 57.000

Tempo pieno

4 giorni fa
Candidati tra i primi

Una candidatura completa in un minuto

Curriculum e lettera di presentazione personalizzati, pronti da inviare.

Supera i filtri ATS

Descrizione del lavoro

The University of Rochester is seeking a Stationary Boiler Fireman to supervise the boiler room operations on rotating shifts and to ensure safe and efficient operation of high pressure boilers and the chilled water plant supporting the River Campus and Medical Center.

Applicants should have a High School diploma and at least 3 years’ experience as a Fireman-Stationary Boilers, with strong understanding of safety practices, logs, gauges, and equipment maintenance.

Competenze

  • High School graduation plus a minimum of 3 years as a Fireman-Stationary Boilers with experience in high pressure steam generation and related equipment.
  • Must demonstrate good judgment, physical stamina, and willingness to work in hot, dusty environments.

Mansioni

  • Take over operations from a prior shift and supervise efficient operation of major equipment.
  • Instruct Firemen in stationary engineering operations and maintenance procedures.
  • Regularly check heating panels and logs; respond to trouble calls and coordinate with maintenance staff.
  • Perform routine startup/shutdown of boilers and chilled water units; monitor readings and adjust as needed.
  • Assist in annual boiler cleaning and maintain a clean work area.

Conoscenze

Boiler operation
Fireman-Stationary Boilers
Shift supervision
Safety compliance

Formazione

High School diploma
Trade school preferred

Strumenti

Dunham Control panels

Descrizione del lavoro

As a community, the University of Rochester is defined by a deep commitment to Meliora - Ever Better. Embedded in that ideal are the values we share: equity, leadership, integrity, openness, respect, and accountability. Together, we will set the highest standards for how we treat each other to ensure our community is welcoming to all and is a place where all can thrive.Job Location (Full Address):390 Elmwood Ave, Rochester, New York, United States of America, 14620Opening:Worker Subtype:RegularTime Type:Full timeScheduled Weekly Hours:40Department:100450 Sustainability & Energy SvcsWork Shift:UR - Rotating (United States of America)Range:UR IUOE 035 HCompensation Range:$31.86 - $41.44The referenced pay range represents the first and last step pay rates for this job, as set forth in the applicable collective bargaining agreement. Individual pay will be set in accordance with terms of the applicable collective bargaining agreement.Responsibilities:With considerable latitude for independent judgment and action, is responsible for instruction and direction of the Stationary Boiler Firemen on a shift and for efficient operation and safety of all related equipment to insure adequate steam supply required to meet the demands of the River Campus and Medical Center complex; and for the operation and safety of the chilled water plant and pumping station to satisfy requirements of the connected areas.SUPERVISION AND DIRECTION RECEIVED: Boiler Room Foreman.SUPERVISION AND DIRECTION EXERCISED: Firemen. MACHINES AND EQUIPMENT USED:I- High Pressure Boilers and Related Equipment.e.g. 150,000 P.P.H. B. and W. with spreader stoker and mechanically driven chain grates; 60,000 P.P.H. Combustion Engineering Boiler with manually op. grates.100,000 P.P.H. B.and W. with jet ignition stoker, and automatic mechanically driven chain grates. Bailey Automatic Boiler controls. Boiler feed water pumps (1 Electric and 3 Turbine Driven).Heavy duty fans. (Forced draft, induced draft, and over-fire air fans.)Electric hydraulic pumps used as motive power for stokers, grates etc.Electric driven centrifugal pumps for heater water supply.Condensate and vacuum pumps.Auxiliary steam turbines. Air compressors as applied to pneumatic controls. Electrically operated lorry (1200 to 1500 lbs. capacity).Reducing valves for controlling steam flow to feed water heater to the Steam Distribution Systems. Hydraulic stoker drive coal handling equipment. Outside air supply dampers. Fluid couplings and oil coolers on induced draft fans.Emergency generators and related switchgear. II- Chilled Water Plant Equipment.e.g. 1500 ton carrier centrifugal refrigeration machine with 1400 H.P. turbine drive. 4500 ton carrier centrifugal refrigeration machine with 4800 H.P. Terry Turbine drive. Chilled water circulating pump (37 1/2 to 100 H.P.-3000 to 6750 gallons per minute capacity). Refrigerant Receiver, Transfer pump. Auxiliary equipment such as: condensate pumps, condensate and cooling water pumps; air ejector condensers, pneumatic unit controls. Terry Turbine Driven- Chilled Water Circulating Pump (342 H.P.-13,500 G.P.M.)III- Pumping Station Equipment:e.g. Air compressor for pneumatically operated condensing water discharge valves. Chlorinator and related controls etc. Mechanical River Water Screens.Electrically-Driven Water Pumps (125 H.P. and 350 H.P.)TYPICAL DUTIES:1.Takes over operations from previous shift operating Engineer and acts as shift supervisor for efficient operation and maintenance of all major and auxiliary equipment in use. 2.Observes all operating equipment, machines, tanks, meters etc.3.Reads and records on daily log sheet all information required for initial hour of shift. 4.Oversees Firemen on duty to assure efficient operation of boilers. 5.Instructs Firemen in stationary engineering operations, procedures and practices as further training for Firemen. 6.Insures lubrication of all pumps, fans, compressors, emergency diesel-generator equipment., etc. 7.Regularly checks all Dunham Control heating panels located in Central Plant.8.Receives and logs all trouble calls and transfer calls to appropriate personnel for service. 9.Follows up service requests. 10. Removes ash and siftings from boilers in use. 11. Tests boiler water to determine amount of treatment to be added and/or blowdown required. 12.Starts and stops chilled water unit as required and hourly logs chilled water unit readings (temperature, pressure, R.P.M.s).13. As required, shuts down 4500 ton refrigeration unit and transfers refrigerant to storage receiver. 14. Checks equipment (at pumping station) and cleans screens as necessary. 15. Regularly inspects and observes all equipment for detection of mechanical malfunctioning. 16. Makes repairs and adjustments to equipment as required. 17. Changes recorder charts at 12 (M).18. Assists in annual boiler cleaning. 19. Keeps work area and equipment clean.20. Performs other related stationary operating duties as required or directed. QUALIFICATIONS: High School graduation (preferably Trade School) plus a minimum of 3 years as a \"Fireman-Stationary Boilers\" which has included instruction and training in the overall operation and maintenance of a high pressure steam generation system and auxiliary equipment. Experience required could vary according to an individual's demonstrated abilities and aptitudes. Requires good judgment, good physical condition, and the willingness to work in an atmosphere where more than normal dirt, dust and heat are presentThe University of Rochester is committed to fostering, cultivating, and preserving an inclusive and welcoming culture to advance the University’s Mission to Learn, Discover, Heal, Create – and Make the World Ever Better. In support of our values and those of our society, the University is committed to not discriminating on the basis of age, color, disability, ethnicity, gender identity or expression, genetic information, marital status, military/veteran status, national origin, race, religion, creed, sex, sexual orientation, citizenship status, or any other characteristic protected by federal, state, or local law (Protected Characteristics). This commitment extends to non-discrimination in the administration of our policies, admissions, employment, access, and recruitment of candidates, for all persons consistent with our values and based on applicable law.
Ottieni la revisione del curriculum gratis e riservata.

o trascina qui il file.

Similar jobs

Offerte di lavoro simili che vale la pena confrontare

IUOE Plant Operator, 2nd Class
IUOE Plant Operator, 2nd Class

001 University of Rochester • Stati Uniti

In loco
USD 44.000 - 57.000
IUOE Plant Operator, 3rd Class
IUOE Plant Operator, 3rd Class

University of Rochester • City of Rochester (NY)

In loco
USD 41.000 - 53.000
IUOE Steamfitter/Plumber A
IUOE Steamfitter/Plumber A

University of Rochester • Stati Uniti

In loco
USD 40.000 - 54.000
Boiler & Chilled Water Plant Operator (Rotating Shifts)
Boiler & Chilled Water Plant Operator (Rotating Shifts)

University of Rochester • City of Rochester (NY)

In loco
USD 44.000 - 57.000
IUOE Mechanic Specialist, Data Ctr.-2
IUOE Mechanic Specialist, Data Ctr.-2

University of Rochester • City of Rochester (NY)

In loco
USD 44.000 - 56.000
Boiler & Chilled Water Plant Operator (Rotating Shift)
Boiler & Chilled Water Plant Operator (Rotating Shift)

001 University of Rochester • Stati Uniti

In loco
USD 44.000 - 57.000
Boiler Plant Operator – Steam Systems & Plant Ops
Boiler Plant Operator – Steam Systems & Plant Ops

University of Rochester • City of Rochester (NY)

In loco
USD 41.000 - 53.000
IUOE Power & Util Mechanic Wrk Ldr
IUOE Power & Util Mechanic Wrk Ldr

University of Rochester • Stati Uniti

In loco
USD 45.000 - 59.000
IUOE Building Mechanic A
IUOE Building Mechanic A

University of Rochester • City of Rochester (NY)

In loco
USD 36.000 - 47.000
IUOE Preventive Mainten Mech, MC
IUOE Preventive Mainten Mech, MC

University of Rochester • City of Rochester (NY)

In loco
USD 30.000 - 38.000