Motion Recruitment seeks a Data Center Field Installations Technician (L2) for a 3‑month contract with potential extension or permanent consideration. Based in Abernathy, TX, you will perform in‑rack installation activities, from rack builds to cable management and power distribution, under minimal supervision.
You will validate cooling integration (DX and direct‑to‑chip liquid cooling), install OS imaging and basic hardware tests, and guide junior technicians while coordinating with project
Come join a thriving Data Center company and gain enough training and experience to be promoted all the way up to Lead position!
Contract length: 3 months with likelihood of extension or being brought on permanently.
Proven experience in data center installations or similar hands‑on technical role
Strong understanding of rack infrastructure, server, storage, and network hardware
Proficiency in structured cabling (fiber and copper) and cable management best practices
Experience with power distribution within racks (PDUs, dual feeds, redundancy concepts)
Working knowledge of cooling methodologies:
DX airflow management within racks
Direct-to-chip (D2C) liquid cooling systems (installation, connection handling, and basic validation)
Physically capable of performing installation tasks in demanding environments
Experience with system deployment activities:
OS installation and imaging tools (e.g., PXE, ISO-based installs, or automated deployment tools)
Basic BIOS/firmware configuration and hardware validation
Familiarity with post-install validation and quality assurance processes
Ability to read and interpret technical drawings, schematics, and MOPs
Strong troubleshooting and problem‑solving skills during installations
Ability to work independently and guide junior technicians
Good understanding of health and safety regulations in data center environments
Physically capable of performing installation tasks in demanding environments
The Data Center Field Installations Technician (L2) is a developing technical role responsible for executing and overseeing in-rack installation activities of moderate complexity within a data center environment. This includes rack builds, equipment installation, structured cabling, power distribution, advanced cooling integration (DX and direct-to-chip liquid cooling), and initial system bring‑up activities.
This role works with greater autonomy and is responsible for interpreting installation designs, validating work quality, and supporting troubleshooting during deployment activities.
Through proactive coordination and problem‑solving, this role ensures installations are completed efficiently, accurately, and in alignment with technical standards and project timelines.
The primary objective of this role is to deliver high‑quality installation and validation outcomes while minimizing delays, rework, and SLA risks.
The Data Center Field Installations Technician (L2) is responsible for managing standard to medium‑complexity installation tasks, guiding L1 technicians, and resolving issues encountered during implementation.
Lead rack build and in‑rack deployment activities based on design documentation
Interpret rack layouts, elevation diagrams, and cabling schematics
Perform and validate rack & stack activities for servers, storage, and network equipment
Execute and verify structured cabling (fiber and copper), including basic testing/validation
Install and validate power connections (single/dual feed, PDUs, load considerations)
Implement and optimize cooling solutions:
Configure airflow best practices for DX-cooled environments
Install and validate direct-to-chip (D2C) liquid cooling systems, including cold plates, hoses, manifolds, and quick disconnects
Perform visual inspections for leaks and ensure proper routing, strain relief, and secure connections
Perform initial system bring‑up activities:
Execute OS installation and basic configuration (in line with build standards and imaging processes)
Validate hardware functionality (POST checks, BIOS/firmware baseline verification)
Perform basic network connectivity checks where required
Conduct post‑installation quality assurance:
Verify installations against design specifications and checklists
Perform cable, power, and labeling audits
Validate airflow and cooling setup (DX and D2C)
Identify and remediate defects or elevate issues
Identify and resolve installation issues, escalating when required
Support and guide L1 technicians on best practices and procedures
Coordinate with project teams, engineering, and operations for smooth delivery
Update documentation and report installation progress and deviations