Get a reply from this employer
Your resume and cover letter, tailored to exactly what they’re hiring for.
Swid Process Technologies Pvt. Ltd. is seeking a Head of Asset Management in Pune to own the post-commissioning portfolio for solar assets. You will oversee customer service, monitoring, performance metrics, and SCADA operations, ensuring maximum plant availability and contract adherence.
The role requires 10+ years in solar O&M/asset management with portfolio leadership, strong knowledge of PV performance, SCADA, and ERP/ticketing. Leadership and cross-functional coordination are essential.
Source: SWID Interactive Master Role Bank, IV4; revised 15 October 2026. Source workbook supplied on 12 November 2026.
Head Asset Management
Operations
Head Operations
Asset Performance and Customer Support Engineer; Service Engineer; SCADA Engineer; Solar Care Manager
Head Operations or nominated senior maintenance professional
Own the post-commissioning portfolio, customer service, monitoring, performance, SCADA, preventive/breakdown maintenance and module-cleaning operations to maximize plant availability, generation, contract compliance and customer retention.
This role remains accountable for the outputs listed above even when work is delegated. During absence or vacancy, the named backup may perform essential transactions within documented authority. Technical approvals, commercial commitments, safety waivers and quality acceptance may be exercised only by a competent and authorized person. Handover must include current trackers, pending actions, access credentials under approved custody, documents and due dates.
Review performance monthly using the specified KPI periods and evidence. Weights total 100% and express relative importance. Assess each KPI against its stated target and approved weight. Non-Sales roles have no exceeds-expectations band. Mandatory requirements remain applicable regardless of weight. Where no activity is due, record not applicable with the reason; do not record zero or invent achievement.
100%
Approved targets retained; hierarchy revised
Normal generation restored across affected equipment within 48 hours
Department: Operations
Target: Within 48 elapsed hours of alert/complaint receipt
Review: Monthly
Measurement method: Normal generation restored across all affected equipment within 48 hours / applicable incidents due x 100.
Weight: 35%
Status: Approved targets retained; hierarchy revised
Service response within six hours
Department: Operations
Target: Within six elapsed hours of alert/complaint receipt
Review: Monthly
Measurement method: Items completed within the specified deadline / items due in the review period x 100; use timestamped records.
Weight: 15%
Status: Approved targets retained; hierarchy revised
Six-month preventive-maintenance completion
Department: Operations
Target: Every six months; 100% scheduled PM completed
Review: Monthly
Measurement method: Items completed within the specified deadline / items due in the review period x 100; use timestamped records.
Weight: 15%
Status: Approved targets retained; hierarchy revised
Cleaning within 15 days or shorter customer-order interval
Department: Operations
Target: Every 15 calendar days or shorter customer-order interval; >=98% schedule adherence
Review: Monthly
Measurement method: Items completed within the specified deadline / items due in the review period x 100; use timestamped records.
Weight: 15%
Status: Approved targets retained; hierarchy revised
Repeat-fault prevention
Department: Operations
Target: Repeat faults <=3%
Review: Monthly
Measurement method: Repeat faults / resolved faults x 100.
Weight: 10%
Status: Approved targets retained; hierarchy revised
Customer communication and performance reports
Department: Operations
Target: 100% monthly reports; satisfaction >=90%
Review: Monthly
Measurement method: On-time reports / due x 100; favourable customer responses / valid responses x 100.
Weight: 10%
Status: Approved targets retained; hierarchy revised
DWR updation and accuracy
Department: Operations
Target: 100% of working days with a complete, accurate DWR
Review: Daily
Measurement method: Working days with a complete and accurate DWR / working days due x 100; verify work evidence, progress, blockers and manager review.
Weight: 0%
Status: Mandatory requirement; no separate weight
1. Engineering degree/diploma, preferably Electrical.
2. 10+ years in solar O&M/service/asset management with portfolio leadership.
3. Strong understanding of PV performance, PR/yield, inverters, SCADA, electrical systems and field maintenance.
4. Customer contracts/SLA, warranty, spares, budgeting and team-deployment skills.
5. Monitoring portals, ERP/ticketing, Excel / Equivalent and analytics proficiency.
6. Leadership, emergency escalation, customer communication and travel readiness.