Senior Mechanical Lead – Data Center Cooling & Reliability

cw

Atlanta (GA)

On-site

USD 90,000 - 140,000

Full time

4 days ago
Be an early applicant
Application generator

Don’t send a generic resume — generate a resume and cover letter tailored to this exact role.

Get past ATS filters

Job summary

Cushman & Wakefield is seeking a Senior Mechanical Lead Technician to oversee maintenance strategy and execution for mission-critical data center cooling systems. You will lead PM, PdM, and corrective maintenance for CRAC/CRAH units, chillers, CDUs, pumps, and cooling towers, ensuring redundancy and thermal stability.

This role requires strong CMMS skills, incident analysis, and collaboration with operations to protect 24/7 uptime.

Qualifications

  • 5-8 years of critical facilities maintenance experience with strong mechanical systems expertise.
  • Experience leading maintenance programs, technical teams, and vendor scopes.
  • Strong CMMS knowledge, including planning, execution, reporting, and data governance.
  • Ability to read and interpret technical drawings, sequence of operations, and system documentation.
  • Proven troubleshooting and root-cause analysis skills in high-availability environments.
  • Working knowledge of OSHA, NFPA, environmental requirements, and applicable codes and standards.
  • Ability to support 24/7 operations, including on-call rotation as required.
  • Relevant trade license or certifications preferred, including CDCP, DCEP, HVAC, controls, or BAS credentials.

Responsibilities

  • Lead mechanical PM, PdM, and corrective maintenance for cooling equipment.
  • Serve as technical authority for cooling redundancy during maintenance.
  • Develop, review, and enforce mechanical SOPs, MOPs, EOPs, and change-control requirements.
  • Plan and approve outages, isolations, lockouts, valve alignments, and flow changes while maintaining required cooling capacity.
  • Implement condition-based maintenance, including vibration analysis, oil analysis, thermography, ultrasonic testing, and water-quality monitoring.
  • Lead root-cause analysis for cooling incidents, leaks, and control failures; track corrective actions through completion.
  • Maintain hydronic system health by monitoring flow, delta-T, pressure, and water chemistry.
  • Coordinate HVAC vendor work and review service reports, test results, and corrective actions for quality and completeness.
  • Support commissioning and recommissioning activities, including equipment performance testing and redundancy validation.
  • Verify post-maintenance performance, including setpoints, airflow, chilled-water temperatures, pressures, and system stability.
  • Maintain accurate CMMS records for mechanical assets, task lists, frequencies, and supporting documentation.
  • Improve airflow management and cooling efficiency through maintenance-driven actions.
  • Identify degradation, capacity constraints, and lifecycle risks; recommend capital repairs or replacements.
  • Ensure compliance with environmental, refrigerant, water-treatment, and site safety requirements.
  • Coordinate maintenance schedules with operations to protect thermal conditions during work.
  • Develop technician capability through training, procedure reviews, and field audits.
  • Support audits, inspections, and client reporting related to mechanical maintenance performance.
  • Drive reliability KPIs, including PM compliance, defect backlog, repeat failures, and corrective action closure.

Skills

Mechanical systems expertise
Maintenance program leadership
Troubleshooting & root-cause analysis
Reading technical drawings
On-call support
Regulatory compliance (OSHA/NFPA)

Tools

CMMS

Job description

Cushman & Wakefield is seeking a Senior Mechanical Lead Technician to oversee maintenance strategy and execution for mission-critical data center cooling systems. You will lead PM, PdM, and corrective maintenance for CRAC/CRAH units, chillers, CDUs, pumps, and cooling towers, ensuring redundancy and thermal stability.

This role requires strong CMMS skills, incident analysis, and collaboration with operations to protect 24/7 uptime.

Get your free, confidential resume review.

or drag and drop your file here.

Similar jobs

Similar jobs worth comparing

Senior Mechanical Lead – Data Center Cooling & Reliability
Senior Mechanical Lead – Data Center Cooling & Reliability

Cushman & Wakefield • Atlanta (GA)

On-site
USD 90,000 - 130,000
Senior Mechanical Lead Technician
Senior Mechanical Lead Technician

Cushman & Wakefield • Atlanta (GA)

On-site
USD 90,000 - 130,000
Senior Mechanical Design Engineer - Data Center Cooling
Senior Mechanical Design Engineer - Data Center Cooling

Worldwidemissioncritical • United States

On-site
USD 100,000 - 150,000
Senior Data Center Mechanical Lead — HVAC & Uptime
Senior Data Center Mechanical Lead — HVAC & Uptime

CSS • Columbiana (AL)

On-site
USD 90,000 - 130,000
Senior Controls Lead Technician: Critical Data Center Automation
Senior Controls Lead Technician: Critical Data Center Automation

cw • Atlanta (GA)

On-site
USD 90,000 - 130,000
Health insurance
Vision insurance
Dental insurance
+6
Senior Data Center Mechanical Engineer — Mission-Critical
Senior Data Center Mechanical Engineer — Mission-Critical

Critical Facility Group • United States

On-site
USD 120,000 - 180,000
Data Center Maintenance & Reliability Lead
Data Center Maintenance & Reliability Lead

cw • Atlanta (GA)

On-site
USD 120,000 - 180,000
Health insurance
Retirement savings plans
Paid time off
+1
Data Center Operations Lead Engineer
Data Center Operations Lead Engineer

cw • Atlanta (GA)

On-site
USD 90,000 - 130,000
Data Center Mechanical Lead - 24/7 Ops & Projects
Data Center Mechanical Lead - 24/7 Ops & Projects

Csquare • Irvine (CA)

On-site
USD 120,000 - 180,000
Data Center Reliability Lead
Data Center Reliability Lead

Cushman & Wakefield • Atlanta (GA)

On-site
USD 103,000 - 122,000
Health, vision & dental
Retirement savings
Paid time off