Quetta Electric Supply Company is seeking an experienced A/C Mechanic (BPS-05) to install, service, and overhaul HVAC systems across headquarters, regional centers, and offices in Balochistan. The role requires handling refrigerants, brazing copper piping, measuring pressures, and performing preventive maintenance to ensure reliable cooling operations.
The ideal candidate will possess matriculation with HVAC experience, strong electrical troubleshooting skills, and familiarity with VRF and
Active Prep BPS-05 NJP-QESCO-10349 QESCO/RECT/2026/01
Official recruitment notification, eligibility criteria, pay scale (BPS-05), quota allocation, and written screening test syllabus for A/c Mechanic in the Quetta Electric Supply Company.
Online applications for this recruitment closed on November 14, 2026. Official screening test syllabus weightages, paper scheme, and practice materials are actively maintained for registered candidates preparing for the upcoming written examination.
A/C Mechanic (BPS-05) offers 1 Post in Quetta Electric Supply Company (Quetta) with an estimated salary package of PKR 24,000 - 33,000 / month (Basic Pay Scale BPS-05) and an age limit of 18 - 35 years (General age relaxation admissible as per Federal Government Rules).
Case Number NJP-QESCO-10349
Department / Ministry Quetta Electric Supply Company
Total Positions 1 Post
Job Type / Status Contract
Place of Posting Balochistan
Age Limit 18 - 35 years (General age relaxation admissible as per Federal Government Rules)
Estimated Base Salary Package PKR 24,000 - 33,000 / month (Basic Pay Scale BPS-05)
Credential Category Matriculation With Technical Experience In Hvac And Refrigeration
Posting Date October 30, 2026
Apply Before November 14, 2026 (Closed)
The A/C Mechanic (BPS-05) at QESCO serves as a skilled HVAC technician responsible for the installation, preventive maintenance, repair, and overhaul of heating, ventilation, air conditioning, and refrigeration systems across QESCO headquarters buildings, regional computer billing centers, grid control rooms, and officer residences. The role involves troubleshooting split air conditioners, package units, inverter heat pumps, precision computer room air conditioners (CRAC), and cold water chillers. Key duties include checking refrigeration system pressures using manifold gauges, detecting refrigerant leaks with electronic halogen detectors or soap bubbles, evacuating systems using dual-stage vacuum pumps, charging refrigerants (R410A, R32, R134a, R22), oxy-acetylene torch brazing of copper tubing, testing electrical compressor motors, servicing PCB control boards, cleaning condenser coils, and maintaining routine service logs.
Quetta Electric Supply Company (QESCO) is a premier public sector electricity distribution utility functioning under the administrative control of the Ministry of Energy (Power Division), Government of Pakistan. Incorporated under the Companies Ordinance 1984, QESCO manages the power distribution infrastructure across 32 districts of Balochistan. Alongside primary electrical transmission lines and grid substations, QESCO maintains extensive technical facilities including computerized billing data centers, automated Supervisory Control and Data Acquisition (SCADA) master control rooms, telecommunication server rooms, regional testing laboratories, and corporate executive directorates. Maintaining precise ambient temperature and humidity control in these critical electronic environments is vital to prevent server overheating, electronic relay tripping, and data corruption.
Practical Trade Test, Brazing Demonstration, and Technical Viva Blueprint
The recruitment examination for the post of A/C Mechanic (BPS-05) in Quetta Electric Supply Company (QESCO) is designed to evaluate practical craftsmanship in refrigeration systems, copper piping fabrication, leak detection, vacuum dehydration, electrical controls troubleshooting, and technical viva voce competence. Candidates are evaluated through an exhaustive hands‑on trade demonstration and an oral interview.
The practical evaluation is conducted in a fully equipped HVAC workshop under the direct observation of the technical evaluation committee:
Refrigeration systems in critical data and control rooms require faultless electrical diagnostics:
Question 1: Explain the four fundamental stages of the vapor compression refrigeration cycle and describe the state of the refrigerant at each stage.
Answer: The cycle consists of four continuous processes: First, Compression: Low-pressure, low-temperature superheated vapor is drawn into the compressor and compressed into high-pressure, high-temperature superheated vapor; Second, Condensation: High-pressure vapor enters the condenser, where ambient air removes latent heat, condensing vapor into high-pressure subcooled liquid; Third, Expansion: High-pressure liquid passes through a capillary tube or expansion valve, undergoing a sudden pressure drop into a cold low-pressure liquid-vapor mixture; Fourth, Evaporation: This mixture enters the evaporator, absorbs heat from indoor air, boils into low-pressure vapor, and returns to the compressor.
Question 2: Why must R410A refrigerant always be charged in the liquid state, and what is temperature glide?
Answer: R410A is a near-azeotropic blend composed of 50 percent R32 and 50 percent R125. Because its components have slightly different boiling points, charging in the vapor state causes fractionation—the refrigerant with the lower boiling point evaporates faster, altering the blend composition and degrading performance. Charging in the liquid phase (by inverting the cylinder) ensures the exact 50/50 proportion enters the system. Temperature glide refers to the temperature difference between the bubble point and dew point at constant pressure; R410A has a negligible glide (less than 0.2 C), behaving almost like a single-fluid azeotrope.
Question 3: Why is moisture considered the most dangerous contaminant in a refrigeration system, and how does it damage the compressor?
Answer: Moisture inside a refrigeration system causes two catastrophic failures: First, Ice Blockage: Moisture cannot dissolve in cold refrigerants; when it reaches the expansion valve or capillary tube where temperatures drop below zero degrees Celsius, water freezes into solid ice crystals, completely choking refrigerant flow and causing the evaporator to starve; Second, Chemical Corrosion and Acid Formation: Under high discharge temperatures and pressures in the compressor, moisture reacts with synthetic polyolester (POE) or mineral refrigeration lubricants and halogenated refrigerants to produce hydrochloric and hydrofluoric acids. These acids dissolve motor winding insulation (causing hermetic compressor burnout), etch valve plates, and cause copper plating on bearings, leading to seizure.
Question 4: What is the purpose of pulling a vacuum down to 500 microns, and why can an ordinary compressor not be used as a vacuum pump?
Answer: Pulling a deep vacuum down to 500 microns (0.5 mm of mercury) is necessary to lower the boiling point of water below ambient temperature, causing any liquid moisture trapped in copper pipes and compressor oil to boil into vapor and be exhausted from the system, while removing non-condensable atmospheric air (oxygen and nitrogen). An ordinary refrigeration compressor cannot be used as a vacuum pump because it has large internal clearance volumes, cannot achieve deep vacuum levels below 25,000 microns, lacks the compression ratio to boil water, and will overheat rapidly when run without refrigerant mass flow and cooling.
Question 5: What is the function of a crankcase heater on a commercial air conditioning compressor?
Answer: A crankcase heater is an electric heating element wrapped around or inserted into the bottom of the compressor crankcase. When the air conditioner is turned off during cold periods, refrigerant vapor in the system naturally migrates toward the coldest point—the compressor—and dissolves into the lubricating oil. During subsequent startup, the sudden pressure drop in the crankcase causes this dissolved liquid refrigerant to boil violently, causing the oil to foam. This oil foam is pumped out through the discharge valves, starving bearings of lubrication and leading to mechanical seizure. The crankcase heater keeps the oil warmer than the rest of the system, driving away refrigerant vapor and preventing liquid slugging.
Week 1: Brazing, Tubing Fabrication, and Piping Assembly
Practice copper pipe cutting, reaming, flaring, and swaging on various pipe diameters. Spend 15 hours practicing oxy-acetylene torch brazing using 5 percent and 15 percent silver-bearing rods. Test every brazed joint under 300 PSI nitrogen pressure to ensure zero porosity and complete penetration.
Week 2: Vacuum Dehydration, Manifold Gauges, and Leak Detection
Practice connecting manifold gauges, vacuum pumps, and electronic micron gauges. Master the procedure for pressurizing split AC systems with dry nitrogen to 350 PSI for 24-hour pressure holding tests. Practice soap bubble leak testing on flare nuts and service valves.
Week 3: Refrigerant Recovery, Charging, and Inverter Troubleshooting
Practice charging refrigerants (R410A, R32, R134a) by precise weight using digital scales. Study inverter DC motor compressors, electronic expansion valves (EEVs), and diagnostic error codes for major brands (Gree, Haier, Dawlance, Mitsubishi). Practice testing sensors, thermistors, and inverter power modules with multimeters.
Week 4: Electrical Controls, Mock Trade Test, and Board Viva
Review compressor electrical terminal testing (C-S-R formulas), capacitor testing, and contactor wiring. Practice answering thermodynamic, environmental, and electrical safety interview questions. Conduct a full timed simulation of copper brazing, vacuum pulling, and electrical testing.