The Office of the Chief Officer, Municipal Corporation Khuzdar is inviting applications for the Fireman (BPS-04) post. The role supports urban sanitation, municipal fleet maintenance, and emergency firefighting within Khuzdar city, under Balochistan government rules.
Candidates must meet the 18–33 (up to 43 with relaxation) age criteria, hold a primary certificate with fitness clearance and Khuzdar domicile, and be ready for a regular public sector appointment with competitive pay and allowances.
Official recruitment notification, eligibility criteria, pay scale (BPS-04), quota allocation, and written screening test syllabus for Fireman in the Office of the Chief Officer, Municipal Corporation Khuzdar.
Online applications for this recruitment closed on November 15, 2026. Official screening test syllabus weightages, paper scheme, and practice materials are actively maintained for registered candidates preparing for the upcoming written examination.
Fireman (BPS-04) offers 8 Posts in Office of the Chief Officer, Municipal Corporation Khuzdar with an estimated salary package of PKR 28,000 - 38,000 / month (Basic Pay Scale BPS-04 plus Fire Risk Allowances) and an age limit of 18 - 33 years (Up to 43 years with 10 years general age relaxation under Balochistan rules).
Department / Ministry Office of the Chief Officer, Municipal Corporation Khuzdar
Total Positions 8 Posts
Job Type / Status Regular
Place of Posting Khuzdar
Age Limit 18 - 33 years (Up to 43 years with 10 years general age relaxation under Balochistan rules)
Estimated Base Salary Package PKR 28,000 - 38,000 / month (Basic Pay Scale BPS-04 plus Fire Risk Allowances)
Credential Category Primary Certificate + Physical Fitness Clearance + District Khuzdar Local/Domicile
Posting Date October 30, 2026
Apply Before November 15, 2026 (Closed)
District Khuzdar Local / Domicile (Balochistan)
The Municipal Corporation Khuzdar, functioning under the administrative oversight of the Local Government and Rural Development Department, Government of Balochistan, officially invites applications from eligible, energetic, and physically fit candidates possessing valid District Khuzdar Local / Domicile for regular appointment to the post of FIREMAN (BPS-04) (BPS-04). Selected personnel will serve within the municipal jurisdiction of Khuzdar city, supporting urban sanitation, municipal fleet maintenance, emergency fire fighting, public horticulture, and civic administrative services.
Core daily responsibilities encompass maintaining robust operational workflows across city wards, commercial bazaars, and municipal offices. Appointees are expected to observe strict workplace safety standards, handle municipal machinery and tooling with meticulous care, adhere to departmental reporting hierarchies, and respond promptly during civic emergencies such as urban flooding, municipal fires, or public health sanitation drives. Candidates must demonstrate honesty, diligence, and unwavering commitment to public service.
This post offers an excellent regular public sector career opportunity under the Government of Balochistan. Appointees receive statutory compensation governed by Basic Pay Scales (BPS), including regular medical allowance, house rent allowance, local compensatory allowances, comprehensive pension benefits, and job security as per Balochistan Civil Servants rules.
Municipal Corporation Khuzdar is the principal urban local government authority governing Khuzdar, the second-largest city and vital educational and transit hub of Balochistan province. Functioning under the Balochistan Local Government Act and the administrative oversight of the Local Government and Rural Development Department, the corporation is mandated with municipal infrastructure management, solid waste disposal, public sanitation, fire and emergency rescue services, urban horticulture, and local civic administration.
The corporation operates emergency fire fighting stations, mechanized waste management fleets, public parks, rest houses, and drainage infrastructure across Khuzdar city. Serving local residents under statutory provincial civil service rules, Municipal Corporation Khuzdar provides regular basic pay scale appointments with provincial allowances, job security, pension entitlements, and community public service roles for local residents of District Khuzdar.
Applications on plain paper addressed to the 'Chief Officer, Municipal Corporation Khuzdar' along with attested copies of national identity card (CNIC), Local / Domicile Certificate (strictly District Khuzdar), educational certificates/sanads, valid LTV driving license (for drivers), and two recent passport-size photographs must be submitted to the Municipal Corporation Khuzdar office on or before 15th November 2026. Government and semi-government servants must apply through proper channel. Oral trade tests and interviews for eligible shortlisted candidates will be conducted on Saturday, 21st November 2026 at Baldia Rest House Khuzdar. Candidates must produce original CNIC, Local/Domicile, and academic documents at the interview. General age relaxation of 10 years is admissible under Government of Balochistan rules. No TA/DA is admissible for tests or interviews.
Mailing / Physical Submission Address Office of the Chief Officer, Municipal Corporation Khuzdar Municipal Corporation Office, Baldia Road Khuzdar, Balochistan - 87300
Document Checklist: Ensure all applications include attested copies of CNIC, educational transcripts, experience certificates, domicile certificate, and recent passport-sized photographs. Incomplete applications or submissions received after the closing deadline (November 15, 2026) will not be entertained.
This master practical trade test curriculum and technical examination manual has been established by the Departmental Selection Committee of the Municipal Corporation Khuzdar for official recruitment to the post of FIREMAN (BPS-04) (BPS-04) on District Khuzdar Local / Domicile Quota under advertisement AB No 482/30-10-2026 (Case No. MC-KHZ/RECT/2026/01). In accordance with Government of Balochistan recruitment rules and statutory municipal service regulations for basic pay scales BPS-01 through BPS-04, eligible candidates are evaluated through a direct hands-on Practical Trade Test (70 Marks) and an Oral Technical Viva Voce (30 Marks), totaling 100 Marks. Candidates must achieve a minimum cumulative score of 50% to qualify for final selection.
The candidate is tested on specialized practical capabilities in Fire Fighting Hose Coupling, Hydrant Pumping, Ladder Climbing & Emergency Rescue Drills. The assessment ensures demonstrated technical competence, correct tooling deployment, rapid fault diagnosis, and adherence to municipal safety protocols under live field conditions.
Assessment Competency Dimension
Evaluated Performance Criteria & Behavioral Indicators
1. Tool Selection, Pre-Trip / Setup & Readiness 15 Marks Immediate identification of correct mechanical hand tools, diagnostic gauges, safety devices, or utility gear prior to commencing work.
2. Procedural & Operational Precision 20 Marks Methodical execution of trade operations, following step-by-step technical procedures, zero damage to municipal machinery, tools, or public assets.
3. Troubleshooting & Rapid Diagnostic Skill 15 Marks Accurate identification of operational abnormalities, mechanical defects, water supply blockages, or emergency hazards, and prompt corrective remediation.
4. Occupational Health & Fire Safety Compliance 10 Marks Strict adherence to PPE usage, biological contamination prevention, machinery moving part safety, road traffic caution, and clean workplace hygiene.
5. Speed, Diligence & Turnout Standards 10 Marks Completion of allocated field exercises within strict time limits, exhibiting disciplined demeanor, professional turnout, and orderly tool care.
Evaluation Dimension
Assessed Knowledge Domain & Articulation
1. Core Trade Theory & Municipal By-Laws 10 Marks Conceptual understanding of municipal public utility operations, equipment mechanics, local sanitation by-laws, and civic administrative duties.
2. Maintenance Schedules & Safety Procedures 10 Marks Knowledge of preventive maintenance intervals, chemical disinfectant dilution, fire extinguisher operation (PASS protocol), and safe handling techniques.
3. Emergency Response & Public Service Ethics 10 Marks Composure under emergency situations, rapid mobilization during flash floods or fires, reporting hierarchy, and disciplined public service ethics.
Candidates will be assigned the following real-world practical tasks under the direct observation of the engineering and municipal evaluation board:
Apparatus, Tooling & Equipment Checklist: Two 30-meter lengths of 65mm canvas delivery fire hose with instantaneous couplings, dividing breeching, adjustable fog branch pipe nozzle, fire hydrant standpipe.
Pre-Operational Readiness & Safety Inspection: Inspect hose couplings for rubber washer gaskets and debris, verify hose is clean and flaked or rolled in Dutch roll configuration.
Step-by-Step Technical Execution Procedure: Run out first 30-meter hose length from fire tender; deploy second hose length; connect male instantaneous coupling into female coupling with sharp click confirming locking lugs engaged; attach branch pipe fog nozzle to delivery end; connect inlet coupling to fire tender discharge outlet; adopt low-profile braced stance; signal pump operator for water ('Water On'); adjust nozzle spray pattern from wide defensive fog shield (for heat protection) to narrow solid jet stream (for deep fire penetration); shut off nozzle slowly to prevent dangerous water hammer shock in hose line.
Crucial Occupational Safety & Operational Precautions: Never step across pressurized hose lines; brace body firmly against reactive back-pressure (up to 30 kg nozzle thrust); wear full fire turnout gear.
Apparatus, Tooling & Equipment Checklist: Open-circuit positive-pressure SCBA set (300 bar composite cylinder), full-face mask with head harness, pneumatic whistle alarm.
Pre-Operational Readiness & Safety Inspection: Inspect cylinder pressure gauge (>270 bar), verify cylinder valve closed, inspect facepiece seal.
Step-by-Step Technical Execution Procedure: Open cylinder valve fully, then back half-turn; confirm cylinder pressure exceeds 270 bar; close valve and observe gauge for 1 minute testing pneumatic seal (pressure drop under 10 bar); bleed air slowly to verify low-pressure whistle alarm sounds at 55 +/- 5 bar; don harness over shoulders; fasten waist belt and chest strap; don facepiece, tightening harness straps from bottom to top; test face seal by inhaling and holding breath; engage positive-pressure demand valve.
Crucial Occupational Safety & Operational Precautions: Never enter toxic smoke atmospheres without verifying low-pressure warning whistle functionality and secure mask seal.
Pre-Operational Readiness & Safety Inspection: Inspect ladder rungs, stringers, pawls (dogs), and extension hauling line for structural integrity; scan overhead for electrical wires.
Step-by-Step Technical Execution Procedure: Carry ladder to building face with partner; position ladder heel at correct distance from wall (one-quarter of working height, approx 75-degree climbing angle); extend fly section smoothly using hauling line until desired window sill level is reached; engage extension pawls firmly onto rungs; foot the ladder by standing on bottom rung with hands gripping stringers; second fireman climbs steadily, maintaining three points of contact (two hands and one foot, or two feet and one hand) looking upward; secure ladder head with lashing rope; demonstrate victim rescue carry down ladder.
Crucial Occupational Safety & Operational Precautions: Always verify safe clearance from overhead high-voltage power lines (minimum 3 meters distance) before pitching ladders.
The evaluation committee conducts an oral examination evaluating theoretical grounding, analytical reasoning, and emergency responsiveness:
Viva Question 1: What are the four classifications of fire, and which extinguishing agent must be selected for each class?
Model Operational Response: Fire classifications and extinguishing agents: (1) Class A (Ordinary Combustibles: wood, paper, textiles, dry grass): Water is the primary agent (cools fuel below ignition temperature). (2) Class B (Flammable Liquids: petrol, diesel, kerosene, paint thinners): Foam, Dry Chemical Powder (DCP), or CO2 (blankets and starves fire of oxygen; never use straight water streams which cause explosive boilover). (3) Class C (Flammable Gases: LPG, methane, natural gas): Dry chemical powder or shut off fuel supply valve before extinguishing. (4) Class E (Energized Electrical Equipment): CO2 or non-conductive Dry Chemical Powder (water is strictly prohibited due to fatal electrocution risk).
Viva Question 2: What is 'Flashover' and 'Backdraft' in structural fire fighting, and how can a fireman identify warning signs?
Model Operational Response: Flashover and Backdraft: (1) Flashover: The near-simultaneous thermal transition when all exposed combustible surfaces in an enclosed burning room reach their auto-ignition temperature (typically 500‑600°C) and ignite simultaneously. Signs: dense black smoke banking down, rollover flames licking across ceiling, and intense radiant heat. (2) Backdraft: An explosive combustion that occurs when fresh air (oxygen) is suddenly introduced into an oxygen-starved, fuel-rich smoldering room. Signs: thick yellowish-brown smoke puffing out and sucking back into cracks under doors, black soot-covered window glass trembling under pressure, and absence of open flames. Prevention: Vertical roof ventilation before opening doors.