Get more replies from employers
Send a job-specific resume in minutes.
One Complete Solution is seeking an experienced O&M professional to lead on-site electrical systems for critical facilities in Malaysia. The role focuses on ACMV oversight, switchgear, UPS, batteries, generators, and building electrical systems including EV chargers.
The successful candidate will have 8+ years in O&M (or 5+ years in other facilities) and be fluent in Mandarin while adept with MS Office. On-call standby and weekend/holiday availability are required.
Jora Malaysia will close on 9th September 2026. Thank you for being with us, we are cheering you on as you continue your career journey.
The individual whom we seek should possess the following:
Degree in any Engineering / Science / Facilities Management or other technical field of study
Highly analytical and possess strong fundamentals and comprehension of Thermodynamics and Fluid Mechanics
Possesses at least 8 years of O&M experience handling ACMV systems in critical facilities (preferably Electrical and Electronics) or 5 years in other facilities
Highly familiar with O&M related MEPF system jargons (eg, HT and LV, RMU, MSB/SSB/DB, TX, etc) and units of measurement (eg, PPM, V, Ohm, A, etc)
Self-driven, innovative and independently drive assigned tasks to satisfactory completion in an output-based environment. Proactive in identifying issues and developing solutions to overcome them
Ability to be on standby and respond outside of office hours
Highly adept with MS Office suite (Word, Excel, PowerPoint)
Proficient in Mandarin (Speaking, Reading, Writing)
In this role, the successful applicant will function as part of the on-site team to ensure timely and quality deliverables of services rendered by OCS to its Client. The successful applicant will function as the focal point accountable for Electrical Systems that cover:
Switchboards: Medium Voltage (11kV) and Low Voltage (415V) distribution system including ATS, Transformers and Switchgears (note: B0 chargeman available on-site)
Critical DC equipment: UPS, Batteries
Generators: Load bank testing, off load testing, functionality and interfacing with other auxiliary components such as exhaust dampers
Building Electrical Systems: Electrical DBs, lighting, street lighting, emergency lighting, EV Chargers
Comply with Client’s process flows on PPM and Reactive Maintenance (RM).
Develop and/or review Method of Procedure (MOPs) document for equipment and/or systems for which PPM or RM is to be executed. This will require close collaboration with both internal team members and with Client representative(s).
Manage, track and ensure timely deliverables of both OCS appointed and managed (i.e, Client’s vendor who is assigned to OCS to manage) vendors.
Collaborate closely with internal team members to ensure internal (OCS) and external (Client) documentation processes are adhered to at all times, In particular, this will require close collaboration with the CMMS Engineer and Admin Executive of OCS at site.
Actively participate in any shutdown and/or major activity that may only be allowed to take place on weekends or on Public Holidays.
Prepare daily/ weekly updates and monthly report summaries as necessary. This will require daily site walks and verification (refer point no. 5 above) as part of the preparation process.
Repair and perform preventive maintenance on afore-listed electrical equipment.
Troubleshoot defective equipment and maintain a snags list of defects that cover specific issues and proposed rectification plans.
Perform daily inspections of the critical equipment.
Supports incident response and mitigation. Prepare Root Cause Analysis (RCA) reports and corrective action
Coordinate with client and vendor for safe execution of any electrical change.
Evaluate vendor proposals for electrical services, parts and PPM works.
Plan manpower to support PPM and others improvement projects.
Monitor critical power, distribution and support systems and facilities to meet or exceed up-time service levels.