Desk Operator - Green Hydrogen

JSW Steel

Ballari District

On-site

INR 400,000 - 500,000

Full time

6 days ago
Be an early applicant
Application generator

An application made for this job — a tailored resume and cover letter that speak straight to the posting.

Get past ATS filters

Job summary

JSW Steel in Vijayanagar, Ballari district, invites applications for a Panel/Desk officer H2 Production. The role involves operating and monitoring the H2 plant from DCS/PLC/SCADA interfaces, ensuring safe shift operations and uninterrupted production.

You will follow SOPs, troubleshoot issues, coordinate with field engineers, and maintain daily production data and product quality. Strong communication and problem-solving skills are essential for success in this position.

Qualifications

  • BE/BTech or Diploma in Mechanical Engineering / Chemical Engineering / Production Engineering / Instrument engineer
  • Minimum 2-5 years of experience in continuous chemical/gas plant operation
  • Hands-on experience with DCS/PLC/SCADA interfaces for H2 manufacturing from electrolysis is a plus

Responsibilities

  • Operate and monitor the H2 plant from DCS/PLC/SCADA interfaces as per SOP.
  • Troubleshoot plant problems, emergencies, startups and shutdowns.
  • Coordinate with field engineers to ensure smooth plant operation.
  • Monitor daily production data and product quality to meet specs.
  • Maintain safety and compliance with IMS standards and SOPs.

Skills

DCS/PLC/SCADA ops
SAP knowledge
Problem solving
Analytical ability
Planning and decision making
Communication skills
Interpersonal skills
Self-motivated
English proficiency

Education

B.E./B.Tech or Diploma in Mechanical/ Chemical/ Production/ Instrument Engineer

Tools

SAP
SCADA

Job description

Purpose - Why does this role exist?

Panel/Desk officer H2 Production To operate and monitor the plant from DCS / PLC / SCADA interface and ensure plants is operated safely in shifts to meet the uninterrupted production and quality.

Organization Chart

Position reports to: Shift Incharge (Green Hydrogen Plant)

Location: JSW Energy Ltd (Vijayanagar)

Positions Reporting: Direct

Key Result Areas (At least four KRAs should be critical - Kindly write CRITICAL against the KRA)

The primary role is to operate and monitor the H2 plant from DCS / PLC / SCADA interface in alignment with Shift Incharge and manager instructions and ensure all day to day operation and emergencies are handled safely to maintain plant integrity.

Key responsibilities:

  • To control, monitor and optimize the process parameter as per SOP in coordination with filed engineers to ensure smooth plant operation.
  • Trouble shoot the plant problems, Emergency handling and Safe plant, startups and shutdowns.
  • Effective control of the manufacturing process in coordination with all stake holders.
  • Quick capturing the Plant process, Standard operating procedures, Trip matrix for H2 plant and associated unit processes.
  • Optimizing the plant parameters to meet the plant efficiencies
  • Able to review and read process documents (PFD / PID / BEP and DEP docs)
  • To adhere to the routine / non-routine change over schedule of the rotary equipments of the plant.
  • Coordination with all other plant shift in charges for utilities, power & other inputs for smooth Shift operation
  • Close monitoring of shutdown & start up activities.
  • Monitoring and recording daily production data.
  • Monitoring and maintaining the product quality to meet customer needs.
  • On the job training of subordinates.
  • Review and updation of SOP, Trip matrix, Dos & Donts for all plant Equipments under operation.
  • Monitoring the safety interlocks of the plants are healthy.
  • Acting as supporting member to incident controller during Emergency.
  • Keeping a close watch & logging of panel readings on critical operating parameters and plant equipments to diagnose problems and potential breakdown symptoms, take corrective actions.
  • To inform shift In charge about any identified deviation in the process parameters, to find its cause and to take corrective actions in consultation with the shift In Charge to ensure the product Quality as per specifications.
  • To participate in Table top exercises, mock drill, EHS audits, safety committee meetings, trainings and other activities related to safety, environment for the organizations growth as and when informed.
  • Compliance to all statutory standards using IMS documents.
  • Familiar to all types of Unit Process and Unit operation involved plants.
  • Refrigeration system Vapor compression and Vapor absorption systems.
  • Pumps All types of Centrifugal, Reciprocating, Metering, Vacuum & diaphragm pumps.
  • Compressors - All types of Centrifugal, Reciprocating & Screw compressor packages for process gas and utility system.
  • Effluent and Process water treatment systems- DM units, ETP, RO + ZLD units.
  • Utility packages Cooling Tower, N2, Instrument air, Process air, Chilling package
  • Process Equipment Packages (Medium / Heavy equipments)
  • High Temperature and Pressure applications.
  • Soft Skills- System and Process Oriented Knowledge of working on DCS (Distributed control system) / PLC & SCADA operations SAP knowledge. Problem Solving & analytical ability. Planning and Decision making skills. Others- Good communication, Interpersonal Skills & Self-motivated. Language Requirement- Excellent English communication skills (Verbal & Written)
Educational Background and Work Experience
Educational Background:
  • B.E / B Tech or Diploma in Mechanical Engineering / Chemical Engineering / Production Engineering / Instrument engineer
Work Experience:
  • Minimum 2 5 years of experience in continuous Chemical / Gas plant operation. Hands on experience in handling critical process operation using DCS / PLC / SCADA interface (H2 manufacturing from electrolysis process relevant experience is an added advantage)
Working relationships - Stakeholders

Internal:

  • Shift Incharge, Field engineers and Technicians
  • All discipline heads (Electrical & Instrumentation / Mechanical / Civil / Process) for smooth O & M activities.
  • EHS Personnel.

External: OEM, Licensors, Service providers, Suppliers, Contractors, Vendors, Consultants, Statutory agencies etc.

Get your free, confidential resume review.
or drag and drop your file here.
Similar jobs

Similar jobs worth comparing

Frontline Executive- Electrical(Green Hydrogen)
Frontline Executive- Electrical(Green Hydrogen)

JSW Steel • Ballari District

On-site
INR 600,000 - 1,000,000
Shift Engineer Carbonation - CF - HMD PY ( 82322910 )
Shift Engineer Carbonation - CF - HMD PY ( 82322910 )

Reliance Industries Limited • Surat

On-site
INR 550,000 - 850,000
Plant Incharge - Panipat ( 82975716 )
Plant Incharge - Panipat ( 82975716 )

Reliance Industries Limited • Panipat

On-site
INR 900,000 - 1,500,000
Plant Incharge - Satna ( 82710352 )
Plant Incharge - Satna ( 82710352 )

Reliance Industries Limited • Satna

On-site
INR 1,200,000 - 2,400,000
Plant Incharge - Panipat ( 82975716 )
Plant Incharge - Panipat ( 82975716 )

Reliance Infrastructure • Panipat

On-site
INR 1,800,000 - 3,000,000
Shift Superintendent-HDPE DMD ( 82454370 )
Shift Superintendent-HDPE DMD ( 82454370 )

Reliance Industries Limited • Bharuch District

On-site
INR 1,200,000 - 1,800,000
Sr Engineer Panel Support KG KKD
Sr Engineer Panel Support KG KKD

Reliance Industries Limited • Kakinada

On-site
INR 1,200,000 - 2,400,000
Shift Superintendent - DTA PCG OGBL ( 82624676 )
Shift Superintendent - DTA PCG OGBL ( 82624676 )

Reliance Industries Limited • Jamnagar

On-site
INR 900,000 - 1,300,000
Field Executive - DTA PP , JMD. ( 82966650 )
Field Executive - DTA PP , JMD. ( 82966650 )

Reliance Infrastructure • Jamnagar

On-site
INR 300,000 - 420,000
Desk Engineer - Operations
Desk Engineer - Operations

JSW Energy • Ballari District

On-site
INR 600,000 - 1,000,000