Staff Data Center Mechanical Engineer (27962)

Supermicro

San Jose (CA)

On-site

USD 200,000 - 245,000

Full time

14 days+

Get a reply from this employer

Your resume and cover letter, tailored to exactly what they’re hiring for.

Get past ATS filters

Benefits offered by this job

Comprehensive benefits package
Potential bonuses and equity awards

Job summary

A leading data center technology provider is seeking a Staff Data Center Mechanical Engineer to design mechanical systems for advanced AI and hyperscale data centers. The role requires expertise in HVAC, management of multidisciplinary teams, and participation in design projects from concept to commissioning. Applicants should have a Bachelor's in Mechanical Engineering, a PE license, and at least 10 years of experience. This position offers a salary range of $200,000 - $245,000.

Qualifications

  • At least 10 years’ experience designing mission-critical or hyperscale data centers.
  • PE license required.
  • Willing to travel up to 50% domestically/internationally.

Responsibilities

  • Lead the mechanical design scope for new and retrofit data centers.
  • Develop and maintain mechanical design standards for all data center programs.
  • Collaborate with other teams to optimize overall facility layout.

Skills

HVAC systems design
Mechanical engineering principles
Team leadership
Project management
Analytical skills

Education

Bachelor’s in Mechanical Engineering

Tools

BIM/Revit
Cooling system technology

Job description

Staff Data Center Mechanical Engineer (27962)

Join to apply for the Staff Data Center Mechanical Engineer (27962) role at Supermicro.

Be among the first 25 applicants. Get AI‑powered advice on this job and more exclusive features.

Supermicro® is a top tier provider of advanced server, storage, and networking solutions for data centers worldwide. Supermicro is the #5 fastest growing company among the Silicon Valley Top 50 technology firms.

Job Summary

Supermicro seeks an experienced staff data center mechanical engineer to design mechanical systems for advanced AI and hyperscale data centers. This role standardizes mechanical frameworks, including OPR and BOD documents, ensuring facilities meet high standards for performance, reliability, and energy efficiency.

Essential Duties and Responsibilities
  • Lead the mechanical design scope for new and retrofit data centers, covering air- and liquid-cooling systems, and design the systems to meet redundancy and efficiency targets.
  • Develop and maintain mechanical design standards, OPRs, and BODs for all Supermicro data center programs.
  • Perform load calculations, system sizing, and equipment selection for pumps, chillers, cooling towers, dry coolers, and heat exchangers.
  • Collaborate with electrical, controls, and architectural teams to optimize overall facility layout, energy use, and serviceability.
  • Provide engineering oversight for plumbing and fire‑protection system design, ensuring full code compliance and integration with mechanical infrastructure.
  • Review consultant and contractor drawings, specifications, and submittals to verify accuracy and adherence to Supermicro standards.
  • Be familiar with OCP standards such as facility design and liquid‑cooling requirements, and with ASHRAE guidelines for thermal management and environmental control.
  • Support commissioning activities, including factory acceptance testing (FAT), site inspections, and integrated systems testing (IST).
  • Identify and evaluate new cooling technologies such as rear‑door heat exchangers, immersion cooling, and liquid‑to‑liquid heat‑transfer systems.
  • Lead energy‑efficiency initiatives aimed at improving PUE and WUE across all projects.
  • Manage mechanical system risk assessments and provide mitigation strategies during design and construction phases.
  • Interface with utilities and permitting authorities to ensure smooth project execution and compliance.
  • Document lessons learned and contribute to continuous improvement of mechanical design templates and workflows.
Additional Responsibilities
  • Mentor engineers and teams as mechanical systems expert.
  • Train internal staff and join design and commissioning events.
  • Assess vendors, review equipment, and test standard components.
  • Keep up with ASHRAE TC 9.9, sustainability, and new mechanical tech for dense computing.
Required Qualifications
  • Bachelor’s in Mechanical Engineering or related field
  • At least 10 years’ experience designing mission‑critical or hyperscale data centers
  • PE license required
  • Expertise in HVAC: chilled‑water, condenser‑water, air‑handling systems
  • Knowledge of wet/dry mechanical systems, plumbing, fire protection
  • Able to lead mechanical design from concept to commissioning
  • Experience managing multidisciplinary teams and external consultants
  • Familiar with U.S. and international codes (ASHRAE, NFPA, ISO, local AHJ)
  • Strong analytical and communication skills; detail‑oriented
  • Willing to travel up to 50% domestically/internationally
Preferred Qualifications
  • Master’s in Mechanical Engineering
  • Data center cooling systems experience, including high‑density and modular integration
  • Skilled in CFD analysis and BIM/Revit for airflow, thermal, and spatial planning
  • Managed mechanical work for prefabricated or modular data centers
  • Proven vendor collaboration, system optimization, and infrastructure delivery
Salary Range

$200,000 - $245,000

The salary offered will depend on several factors, including your location, level, education, training, specific skills, years of experience, and comparison to other employees already in this role. In addition to a comprehensive benefits package, candidates may be eligible for other forms of compensation, such as participation in bonus and equity award programs.

EEO Statement

Supermicro is an Equal Opportunity Employer and embraces diversity in our employee population. It is the policy of Supermicro to provide equal opportunity to all qualified applicants and employees without regard to race, color, religion, sex, sexual orientation, gender identity, national origin, age, disability, protected veteran status or special disabled veteran, marital status, pregnancy, genetic information, or any other legally protected status.

Get your free, confidential resume review.

or drag and drop your file here.

Similar jobs

Similar jobs worth comparing

Staff Data Center Electrical Engineer
Staff Data Center Electrical Engineer

Supermicro • San Jose (CA)

On-site
USD 175,000 - 200,000
Sr. Datacenter Solutions Engineer
Sr. Datacenter Solutions Engineer

Supermicro • Wayne (CA)

On-site
USD 120,000 - 140,000
Bonus potential
Equity programs
Comprehensive benefits
Data Center Electrical Engineer (30062)
Data Center Electrical Engineer (30062)

Supermicro • San Jose (CA)

On-site
USD 110,000 - 120,000
Sr. Datacenter Solutions Engineer
Sr. Datacenter Solutions Engineer

Supermicro • San Jose (CA)

On-site
USD 120,000 - 140,000
Staff Data Center Solutions Architect (30350)
Staff Data Center Solutions Architect (30350)

Supermicro • San Jose (CA)

On-site
USD 195,000 - 225,000
Sr. Manager - Data Center Development (28721)
Sr. Manager - Data Center Development (28721)

Supermicro • San Jose (CA)

On-site
USD 175,000 - 195,000
Staff Data Center Solutions Architect (29112)
Staff Data Center Solutions Architect (29112)

Supermicro • San Jose (CA)

On-site
USD 155,000 - 180,000
Staff Data Center Solutions Architect
Staff Data Center Solutions Architect

Supermicro • San Jose (CA)

On-site
USD 195,000 - 225,000
Staff Data Center Architect (29309)
Staff Data Center Architect (29309)

Supermicro • San Jose (CA)

On-site
USD 200,000 - 220,000
Staff Data Center Solutions Engineer (29832)
Staff Data Center Solutions Engineer (29832)

Supermicro • San Jose (CA)

On-site
USD 165,000 - 200,000