Stand out for this role — generate a tailored resume and cover letter in about a minute.
The Indiana State Department of Health seeks a microbiologist to perform full-range microbiology analyses on clinical specimens, including culture, PCR, sequencing, and WGS for enteric pathogens such as Salmonella, E. coli, Shigella, Vibrio, Listeria, and Campylobacter.
Responsibilities include documenting QC/QA per CLIA, maintaining records, and potential cross-training in molecular, serological, and other techniques to support routine testing and provide backup capacity.
Incumbent is responsible for coordinating and performing the full range of microbiological examinations and analyses including culture, biochemical tests, EIA, serotyping, PCR, and WGS of clinical specimens for isolation and identification of enteric bacteria including but not limited to Salmonella, E.coli, Shigella, Vibrio, Listeria and Campylobacter. Incumbent will also be responsible for the documentation of all quality control and quality assurance activities according to CLIA regulations. In addition, this position may cross-train in other areas of the lab that may include molecular, microbiological, viral, serological, and other techniques to support routine testing and provide backup capacity.
Incumbent will have in-depth knowledge and ability in the area of microbiology and molecular biology and is able to perform laboratory associated assays or the ability to learn these techniques upon successful completion of proficiency testing. Representative duties include:
The testing personnel are responsible for specimen processing, test performance and for reporting test results.
(a) Each individual performs only those high complexity tests that are authorized by the laboratory director and require a degree of skill commensurate with the individual’s education, training or experience, and technical abilities.
(b) Each individual performing high complexity testing must—
(1) Follow the laboratory’s procedures for specimen handling and
processing, test analyses, reporting and maintaining records of patient
test results;
(2) Maintain records that demonstrate that proficiency testing samples are
tested in the same manner as patient specimens;
(3) Adhere to the laboratory’s quality control policies, document all quality
control activities, instrument and procedural calibrations and
maintenance performed;
(4) Follow the laboratory’s established policies and procedures whenever
test systems are not within the laboratory’s established acceptable levels
of performance;
(5) Be capable of identifying problems that may adversely affect test
performance or reporting of test results and either must correct the
problems or immediately notify the general supervisor, technical
supervisor, clinical consultant, or director;
(6) Document all corrective actions taken when test systems deviate from
the laboratory’s established performance specifications; and
(7) Except as specified in paragraph (c) of this section, if qualified under §
493.1489(b)(5), perform high complexity testing only under the onsite,
direct supervision of a general supervisor qualified under § 493.1461.
(c) Exception. For individuals qualified under § 493.1489(b)(5), who were performing
high complexity testing on or before January 19, 1993, the requirements of
paragraph (b)(7) of this section are not effective, provided that all high complexity
testing performed by the individual in the absence of a general supervisor is
reviewed within 24 hours by a general supervisor qualified under § 493.1461.
Extensive knowledge of the principles, theories and practices of microbiology and related sub- specialties;
Incumbent is engaged in scientific analyses that demand accuracy and demonstrated proficiency in applying laboratory analytical skills to select pertinent guidelines and formulated plans for problem solving. Projects involve many complex variables of great intricacy and the microbiologist is often called upon to analyze and identify unusual specimens/samples. Work requires use of analytical judgment and technical knowledge in order to draw accurate, logical conclusions. Incumbent will also be required to develop and research new testing procedures.
Incumbent works independently as an expert in the assigned area. Technical and/or detailed instruction is provided only upon request when necessitated by a procedural change and/or special project. Incumbent maintains established safety practices when working with materials that have a chemical hazard or biohazard potential. Reports are reviewed for general technical accuracy; however, tasks are performed independently. Errors in work could adversely affect the health, safety and well being of the incumbent or coworkers.
Incumbent works with supervisor and with other State Department of Health staff such as Laboratory Safety Officer and/or external entities (e.g. local health departments, etc.) to devise and implement work procedures and information dissemination. Individual will have contact with employees and the public as a laboratory expert and in the explanation of laboratory procedures and recommendations when appropriate.
The required personal protective equipment can be cumbersome and awkward. Extra effort and concentration will be necessary to perform routine laboratory manipulations under these conditions.