Mechanical Critical Facility Technician 2 - Columbus, OH with Security Clearance

Unofficial M.C. Dean

Columbus (OH)

On-site

USD 70,000 - 98,000

Full time

2 days ago
Be an early applicant
Application generator

An application made for this job — a tailored resume and cover letter that speak straight to the posting.

Get past ATS filters

Job summary

M.C. Dean is seeking a Mechanical Critical Facility Technician to maintain and repair complex HVAC and mechanical systems in mission-critical environments such as data centers, hospitals, and manufacturing facilities.

Ideal candidates will have 6+ years of related experience, EPA 608 certification or the ability to obtain it within 90 days, and be prepared to pursue a Secret clearance. This role requires physical stamina and proficiency with CMMS and BMS platforms.

Qualifications

  • High school diploma or GED required.
  • 6+ years in a critical facility operation (data center/hospital).
  • EPA 608 certification preferred or must obtain within 90 days.
  • Ability to obtain and maintain Secret clearance.
  • Experience with chillers (>300 tons), boilers, and relevant mechanical systems.
  • Must pass NITC Journey Level HVAC exam within first year.

Responsibilities

  • Maintain and repair complex mechanical systems in data centers, hospitals, and manufacturing plants.
  • Operate, maintain, and repair HVAC systems: chillers, boilers, CRAC/CRAH units, AHUs.
  • Install, maintain, and repair minor plumbing systems (pumps, valves, piping).
  • Read and interpret mechanical, plumbing, and electrical diagrams.
  • Use CMMS to track work orders and maintenance activities.

Skills

HVAC expertise
Mechanical systems
Reading diagrams
Physical stamina

Education

High school diploma or GED

Tools

CMMS
Niagara Tridium
Siemens
Johnson Controls

Job description

Overview About M.C. Dean M.C. Dean is Building Intelligence. We design, build, operate, and maintain cyber-physical solutions for the nation's most mission-critical facilities, secure environments, complex infrastructure, and global enterprises. With over 7,000 employees, our capabilities span electrical, electronic security, telecommunications, life safety, automation and controls, audiovisual, and IT systems. Headquarters in Tysons, Virginia, M.C. Dean delivers resilient, secure, and innovative power and technology solutions through engineering expertise and smart systems integration. Why Join Us? Our people are passionate about engineering innovation that improves lives and drives impactful change. Guided by our core values-agility, expertise, and trust-we foster a collaborative and forward-thinking work environment. At M.C. Dean, we are committed to building the next generation of technical leaders in electrical, engineering, and cybersecurity industries. Clearance Requirement: Applicants selected will be subject to a government security investigation and may meet eligibility requirements, including U.S. Citizenship, for access to classified information; Ability to obtain and maintain a Secret clearance. License/Certification Requirement: * Candidates who have already passed the NITC Journey-Level HVAC Exam are preferred; however, the ability to pass the exam within one year of hire is required.

  • Current EPA 608 certification preferred; or must obtain one within 90 days of hire. Responsibilities A Mechanical Critical Facility Technician is responsible for maintaining and repairing the complex mechanical systems in data centers, hospitals, and manufacturing plants. This role requires a strong background in HVAC and other mechanical equipment, along with mission-critical experience and relevant certifications. * Technicians must be proficient in the operation, maintenance, and repair of complex heating, ventilation, and air conditioning systems. This includes chillers, boilers, CRAC/CRAH units, and air handling units.
  • The ability to install, maintain, and repair minor plumbing systems, including pumps, valves, and piping, is required. Experience with hydraulic and pneumatic systems is necessary for troubleshooting and repairing mechanical equipment. Knowledge of BMS platforms like Niagara Tridium, Siemens, or Johnson Controls is crucial for monitoring and controlling environmental systems. Technicians must be able to read and interpret mechanical, plumbing, and electrical diagrams to perform maintenance and repairs. Proficiency with CMMS software is needed for tracking and documenting work orders, repairs, and maintenance activities. Qualifications * Applicants must have a high school diploma or GED or greater * Applicants must have 6+ years' work experience including 3+ years of direct experience in a critical facility operation, such as a data center or hospital. Applicants selected will be subject to a government security investigation and must meet eligibility requirements, including U.S. Citizenship, for access to classified information; Ability to obtain and maintain a Secret clearance. * Applicants identified as Mechanical shall have experience with chillers greater than 300 tons, boilers, or significant other mechanical experiences * Must pass the NITC Journey Level HVAC exam within the first year of employment. * Must possess an EPA 608 Certification Abilities: * The position requires the ability to lift, carry, and move objects weighing up to [50 pounds] on a regular basis. Candidates must demonstrate physical strength and stamina to perform various tasks, including but not limited to, loading, and unloading, operating equipment, and assisting in the transportation of various materials. Proper lifting techniques and safety protocols must be followed to ensure personal and team safety. Relocates a 12-foot stepladder without assistance. * Works at various heights up to 60 feet and can climb and maintain balance on scaffolds, aerial lifts, catwalks and all types of ladders. * Walks, climbs, lifts, squats, crawls, kneels, pushes, pulls and reaches overhead on a routine and repetitive basis. * Possess good vision (may be corrected vision), the ability to see in color, and the ability to hear and communicate in English. * May use a standard ladder without exceeding the weight limit while carrying tools. * Tell when something is wrong or is likely to go wrong. It does not involve solving the problem, only recognizing there is a problem. * Apply general rules to specific problems to produce answers that make sense. * Combine pieces of information to form general rules or conclusions (including finding a relationship among seemingly unrelated events). * See details at close range (within a few feet of the observer). * Listen to and understand information and ideas presented through spoken words and sentences. #INDCooper
Get your free, confidential resume review.
or drag and drop your file here.
Similar jobs

Similar jobs worth comparing

Mechanical Critical Facility Technician 2 - Columbus, OH
Mechanical Critical Facility Technician 2 - Columbus, OH

M.C. Dean, Inc. • Columbus (OH)

On-site
USD 55,000 - 85,000
Mechanical Critical Facility Technician 2 - Columbus, OH
Mechanical Critical Facility Technician 2 - Columbus, OH

M.C. Dean • Columbus (OH)

On-site
USD 75,000 - 95,000
Mechanical Critical Facility Technician 2 (U) - Hawaii with Security Clearance
Mechanical Critical Facility Technician 2 (U) - Hawaii with Security Clearance

Unofficial M.C. Dean • Honolulu (HI)

On-site
USD 47,000 - 69,000
Competitive salary
Medical, dental, vision, life, anddis
Paid time off
+4
Mechanical Critical Facility Technician 4 (U) - Hawaii with Security Clearance
Mechanical Critical Facility Technician 4 (U) - Hawaii with Security Clearance

Unofficial M.C. Dean • Honolulu (HI)

On-site
USD 66,000 - 95,000
Health benefits
Paid time off
401k plan
+2
Mechanical Critical Facility Technician 2 (U) - Hawaii
Mechanical Critical Facility Technician 2 (U) - Hawaii

M.C. Dean, Inc. • Honolulu (HI)

On-site
USD 70,000 - 90,000
Medical, dental, vision insurance
Paid time off
Tuition reimbursement
+2
Mechanical Critical Facility Technician 2 - Ogden, UT
Mechanical Critical Facility Technician 2 - Ogden, UT

M.C. Dean, Inc • Ogden (UT)

On-site
USD 60,000 - 80,000
Mechanical Critical Facility Technician 4 (U) - Hawaii
Mechanical Critical Facility Technician 4 (U) - Hawaii

M. C. Dean • Honolulu (HI)

On-site
USD 68,880 - 74,390
Competitive salary
Medical, dental, vision, life, and dis
Paid time off
+4
Mechanical Critical Facility Technician 2 - San Antonio, TX
Mechanical Critical Facility Technician 2 - San Antonio, TX

M.C. Dean • San Antonio (TX)

On-site
USD 60,000 - 75,000
Competitive salary
Medical, dental, vision insurance
Paid time off
+2
Mechanical Critical Facility Technician 4 (U) - Hawaii
Mechanical Critical Facility Technician 4 (U) - Hawaii

M.C. Dean, Inc. • Honolulu (HI)

On-site
Competitive salary
Medical, dental, vision, life, and dis
Paid time off
+2
Critical Facility Technician 4 (Mechanical/HVAC Focus) - United Kingdom
Critical Facility Technician 4 (Mechanical/HVAC Focus) - United Kingdom

M.C. Dean, Inc • Tysons (VA)

On-site
GBP 65,000 - 90,000