Compensation: $45–$50 per hour, based on experience
Industry: Data Centers | Critical Infrastructure | DC Power
Position Summary
We are seeking an experienced L4 Principal Installer to serve as the senior technical authority for complex DC power installations across the United States.
This position is responsible for overseeing Tier IV installations, live -48V DC power plant replacements, brownfield retrofits, MOP approvals, final Quality Assurance, and Integrated Systems Testing.
The ideal candidate brings extensive experience in mission-critical environments and can make high-impact technical and safety decisions under pressure. You will ensure that every installation completed by internal teams, external contractors, and equipment manufacturers meets the highest standards of safety, reliability, and engineering precision.
Key Responsibilities
1. Engineering and Design Validation
- Review Issued for Construction, or IFC, drawings before equipment deployment.
- Validate load calculations, cable sizing, voltage drop, cable routing, grounding, thermal management, and redundancy requirements.
- Identify technical or design conflicts before equipment is delivered or installed.
- Serve as the final reviewer and approver for Methods of Procedure, or MOPs, prepared by L1–L3 technicians.
- Evaluate the risks associated with energized work and develop contingency plans for worst-case scenarios.
- Establish standardized installation manuals, labeling requirements, and torque specifications.
- Lead complex Tier IV data center installations and multimillion-dollar critical power projects.
- Oversee the replacement and modernization of live -48V DC power plants.
- Execute brownfield retrofits while maintaining N+1 redundancy and uninterrupted facility operations.
- Coordinate technical activities with equipment manufacturers, including Vertiv, Schneider Electric, and Eltek.
- Manage third-party electrical contractors and internal installation teams.
- Resolve complex grounding loops, electromagnetic interference, thermal issues, and power-quality conditions escalated by field teams.
3. Quality Assurance and Final Commissioning
- Serve as the final Quality Assurance authority for critical DC power installations.
- Verify cable routing, terminations, polarity, grounding, labeling, torque values, and commissioning documentation.
- Lead Integrated Systems Testing and final Level 5 commissioning.
- Simulate utility power loss and other failure scenarios.
- Confirm that DC plants, battery systems, AC UPS systems, Automatic Transfer Switches, and generators respond as engineered.
- Review testing results and determine whether installations are ready for final acceptance.
4. Compliance and Risk Management
- Conduct live-work risk assessments and establish safe work zones in high-density environments.
- Serve as the on-site Stop Work Authority when a process is unsafe or technically flawed.
- Ensure compliance with:
- National Electrical Code
- NFPA 70E
- IEEE 1188
- IEEE 450
- Applicable site-specific safety requirements
- Lead investigations involving installation failures, outages, or near-miss events.
- Complete root-cause analyses and present findings and corrective actions to leadership.
5. Leadership and Technician Development
- Create technical training programs for L1–L3 installation technicians.
- Develop and administer practical examinations for technician advancement.
- Mentor technicians in DC power architecture, safe work practices, troubleshooting, and quality standards.
- Establish consistent installation practices across internal teams, contractors, and project locations.
- Promote a culture of technical excellence, accountability, and safety.
Required Qualifications
Professional Experience
- At least 12 years of experience in DC power, telecommunications power, data centers, or critical facilities.
- At least five years of experience leading multimillion-dollar installation projects.
- Demonstrated experience with live -48V DC power plant installations, upgrades, or replacements.
- Experience leading brownfield retrofits in active, high-availability environments.
- Experience reviewing and approving MOPs involving energized or high-risk work.
- Experience reviewing IFC drawings and identifying technical or engineering issues.
- Experience leading final commissioning, Integrated Systems Testing, or Level 5 testing.
- Previous responsibility for final QA approval or sign-off.
- Experience supervising internal technicians, OEM representatives, and third-party electrical contractors.
Technical Knowledge
- Expert knowledge of the National Electrical Code and NFPA 70E.
- Strong knowledge of IEEE 1188 and IEEE 450 battery maintenance standards.
- Advanced understanding of DC power architecture and its interaction with:
- AC UPS systems
- Automatic Transfer Switches
- Standby generators
- Battery systems
- Battery monitoring systems
- Ability to conduct energized-work risk assessments.
- Ability to maintain N+1 redundancy during critical installations.
- Ability to independently diagnose grounding, EMI, thermal, battery, and power-quality issues.
Advanced proficiency with:
- Power-quality analyzers
- Infrared thermography equipment
- Battery impedance testers
- Ground resistance testers
- Insulation resistance testers
- Digital low-resistance ohmmeters
- Clamp meters and related electrical testing equipment
Preferred Education and Certifications
Education or Licensing
One of the following is strongly preferred:
- Bachelor’s degree in Electrical Engineering
- Degree in a related engineering or technical discipline
Preferred Certifications
- RCDD, Registered Communications Distribution Designer
- DCDC, Data Center Design Consultant
- OSHA 30
- NFPA 70E
- CPR and First Aid
- Expert-level certifications from Vertiv, Schneider Electric, Eltek, or other major DC power manufacturers
Travel and Availability Requirements
- Ability and willingness to travel extensively throughout the United States.
- Flexibility to support nights, weekends, extended project assignments, and emergency deployments when required.
- Ability to work inside active data centers and mission-critical facilities.
- Valid driver’s license and ability to meet company travel requirements.
- Ability to work safely in environments involving energized electrical equipment, battery systems, and active critical infrastructure.
Ideal Candidate Profile
You will be successful in this role if you are:
Decisive and composed under pressure
Willing to stop work when safety or system reliability is at risk
Highly experienced in live critical-power environments
Comfortable serving as the final technical and QA authority
Precise when reviewing drawings, MOPs, and commissioning documentation
Skilled at converting engineering requirements into field execution
Confident leading technicians, contractors, engineers, and OEM partners
Focused on preventing outages, technical failures, and safety incidents
Available for extensive nationwide travel
Why Join Us?
- Competitive compensation of $45–$50 per hour, based on experience.
- Opportunity to lead technically demanding DC power projects nationwide.
- Direct involvement in mission-critical data center installations and live brownfield retrofits.
- Opportunity to work with equipment from Vertiv, Schneider Electric, Eltek, and other leading manufacturers.
- Authority to influence safety, Quality Assurance, MOP approval, and commissioning standards.
- Opportunity to develop installation standards and mentor the next generation of critical-power technicians.
#NowHiring #L4Installer #PrincipalInstaller #DCPower #CriticalFacilities #DataCenterJobs #NationwideJobs #TravelJobs #CriticalPower #ElectricalJobs #NFPA70E #NEC #Commissioning #BrownfieldRetrofit #MissionCritical #Vertiv #SchneiderElectric #Eltek