Critical Infra Power SME

GBIT (Global Bridge InfoTech Inc)

Plano (TX)

Hybrid

USD 90,000 - 130,000

Full time

45 hours ago
Be an early applicant
Application generator

Turn this role into an interview — a resume and cover letter built around what this employer wants.

Get past ATS filters

Job summary

GBIT (Global Bridge InfoTech Inc) in Plano, TX seeks an Enterprise Critical Infra Power SME to design and validate MDF/IDF spaces, focusing on power, cooling, and environmental controls.

The role requires SaFE and PMP practices, coordination with facilities and contractors, and the ability to travel as needed to meet site needs.

The candidate will collaborate with IT infrastructure teams to ensure standardization and reliable operations across multiple sites.

Qualifications

  • Experience and ability to manage a technology construction project from concept through completion.
  • Familiarity with IT industry teams and terminology.

Responsibilities

  • Perform/validate IT heat-load calculations for MDF/IDF spaces and ensure cooling capacity.
  • Validate airflow, temperature differential, humidity control, and equipment placement to prevent hotspots.
  • Coordinate with facilities vendors to ensure HVAC installation and sign-off.
  • Establish environmental targets aligned with ASHRAE guidance and monitor sensor placement.

Skills

SAFe familiarity
PMP familiarity
MS Word
Excel
PowerPoint
Microsoft Project
Blueprints
Construction coordination
Electrical terms
HVAC knowledge
Project management

Education

Bachelor’s degree in Architecture
Bachelor’s degree in Electrical Engineering
Bachelor’s degree in Mechanical Engineering
ISO 9001 qualification

Tools

Microsoft Project

Job description

Role: Enterprise Critical Infra Power SME
Location: Plano, TX - (Hybrid with Travel required)

This role is designed to deliver Server and Network main distribution frame (MDF) and IDF spaces. There is project governance that must be adhered to client practices in a SaFE Scaled Agile & PMP framework for projects. Having familiarity with SaFE & PMP project methodologies is required. This role requires selecting physical abilities such as using ladders, stairwells, moving power whips, racking, and selecting compute devices. The role is to implement a best-in-class standards regime for server room builds and transition to the local site to meet their business needs.

Responsibilities:
  • Perform/validate IT heat-load calculations for MDF/IDF spaces using deployed hardware power draw (kW) and convert to BTU/hr. Ensure cooling is sized for current load + growth margin.
  • Validate mechanical design assumptions including airflow, temperature differential, humidity control, and equipment placement to prevent hotspots.
  • Coordinate with Facilities/mechanical vendors to ensure HVAC is installed, commissioned, and verified prior to rack & stack; document test results and readiness sign-off.
  • Establish/verify environmental targets aligned with ASHRAE guidance for IT spaces (temperature/humidity operating range) and confirm monitoring points/sensor placement.
Qualifications:
  • Experience and ability to manage a technology construction project from concept through completion.
  • Familiarity with IT industry teams. Such as but not limited to: Infrastructure Compute, Infrastructure network, IT-OT, storage, TCP/IP, and most common IT terminology.
  • Proficiency with Microsoft Word, Excel, Project, and PowerPoint
  • Deep technical expertise and Proficiency with UPS (Uninterrupted Power Supply), mechanical (cooling), and electrical terms and best practices Electrical terms such as, but not limited to single phase, three phase power, transformers, surge protection devices
  • Proficiency on (but not limited to) ANSI/TIA-568, TIA-569, TIA-606, J-STD-607, NFPA 70 (NEC), ASHRAE, and BICSI TDMM standards, norms and practices.
  • Ability to manage several physical/construction tasks simultaneously. Including but not limited to:
  • Familiar with blueprints and design concepts.
  • Familiar with electrical terms, building code, NEC and NEMA
  • Experience with OSHA and workplace safety guidelines
  • Experience working and partnering with General Contractors, electricians, mechanical technicians, carpenters, high and low voltage wiring personnel.
  • Ability to work in construction spaces: inside, outside, all weather conditions, warehouse spaces
  • Proficient skills with mathematics, measurements, temperature gradients, humidity terms is a must
  • Ability to work in non-conventional spaces: ladders, catwalks, conveyer belts, rooftops, and scissor lifts.
  • Precision and attention to detail is a must and enforceable
  • Deliver consistent results at one and all sites with the exact same results
  • Select travel when approved
  • Regular written updates and status reports
  • Demonstrated experience performing cooling capacity sizing for IT rooms (MDF/IDF), including kW load planning, BTU/hr conversion, and HVAC capacity validation (tons).
  • Working knowledge of airflow management best practices (hot/cold aisle concepts, blanking panels, cable management to reduce airflow blockage).
  • Ability to interpret technical proposals and validate against IT load requirements.
Experiences and Education:
  • Bachelor’s degree in architecture, Electrical, Mechanical or 7 years relevant experience in a construction or architectural role.
  • ISO 9001 qualification is a plus
  • 5+ years proficiency with Microsoft suite of business tools (Word, Excel, PowerPoint Project)
  • Ability to deliver on tight deadlines and manage multiple deliverables.
  • Ability to work with several vendors competing to work in tight spaces simultaneously.
  • Ability to pivot and refocus on an immediate need on demand
  • Proficiency with structured cabling standards: copper, fiber, and UTP.
  • Precision and attention to detail is a must and enforceable
  • Preferred: Experience with critical facilities environments (UPS, Generator/ATS, power redundancy)
Get your free, confidential resume review.
or drag and drop your file here.
Similar jobs

Similar jobs worth comparing

Infrastructure Manager
Infrastructure Manager

HCLTech • Town of Texas (WI)

On-site
USD 90,000 - 135,000
Power Engineer 3 - Suwanee, GA
Power Engineer 3 - Suwanee, GA

M.C. Dean, Inc. • Suwanee (GA)

On-site
USD 75,000 - 95,000
Critical Facilities Electrical Consultant SME Remote Traveler
Critical Facilities Electrical Consultant SME Remote Traveler

Peter Kazella and Associates, Inc • Ashburn (VA)

Remote
USD 120,000 - 180,000
Medical insurance
401(k) plan
Referral bonuses
Datacenter & Infrastructure Engineer
Datacenter & Infrastructure Engineer

Tekvana Inc • Irving (TX)

On-site
USD 60,000 - 78,000
Data Center Specialist
Data Center Specialist

Rentec • Setauket (NY)

On-site
USD 90,000 - 130,000
Immediate Need - DC Infrastructure Technician III / Lead
Immediate Need - DC Infrastructure Technician III / Lead

Bold New Solutions - BNS Power • Hillsboro (OR)

On-site
USD 110,000 - 160,000
401(k)
Dental insurance
Health insurance
+1
Critical Facilities Electrical Consultant SME Remote / Traveler
Critical Facilities Electrical Consultant SME Remote / Traveler

Gilder Search Group • Ashburn (VA)

Remote
USD 120,000 - 160,000
Competitive salary
Medical insurance
401(k) plan
Manager, Facilities Operations Engineer
Manager, Facilities Operations Engineer

Jobtailor • Illinois

On-site
USD 110,000 - 170,000
Senior Project Manager, Data Centers
Senior Project Manager, Data Centers

JLL • Pittsburgh

On-site
USD 150,000 - 200,000
Electrical Project Engineer
Electrical Project Engineer

EPITEC • Dearborn (MI)

On-site
USD 70,000 - 100,000