Critical Facilities Technician (DISA OKC) 10PM - 6:30AM

EMCOR Government Services

Oklahoma City (OK)

On-site

USD 39,000 - 50,000

Full time

14 days+
Application generator

An application made for this job — a tailored resume and cover letter that speak straight to the posting.

Get past ATS filters

Job summary

EMCOR Government Services, Inc. seeks an energetic Critical Facilities Technician to serve as a technical resource and leader for DISA Data Centers in Oklahoma City, OK.

This role ensures high availability and reliability of electrical, mechanical, HVAC, and life-safety equipment within the data center. The technician will troubleshoot, operate, and maintain mission-critical infrastructure, including generators, UPS, switchgear, PDUs, CRAC/CRAH units, and BAS controls, targeting uptime better

Qualifications

  • Must have at least three years experience in a data center or mission-critical environment.
  • Active State Journeyman Electrician or Journeyman HVAC license per Oklahoma rules.
  • Familiarity with generators, switchgear, UPS, PDUs, CRAC/CRAH units, and chillers.

Responsibilities

  • Oversee and maintain critical data center infrastructure for reliability and SLA compliance.
  • Support installation, maintenance, and repair of electrical, mechanical, and HVAC systems.
  • Monitor and respond to abnormal conditions across mechanical, electrical, fire/life safety, and control systems.
  • Coordinate with third-party vendors and ensure PM activities meet contract requirements.
  • Participate in on-call rotation and lead system recovery efforts when issues arise.

Skills

Data center electrical systems
Data center mechanical systems
NFPA 70E/OSHA safety
Reading schematics/diagrams
MS Office/CMMS
Onsite work
Communication in high-stress env

Education

High School Diploma or GED

Tools

MS Office
CMMS
IR camera
Multimeter

Job description

About Us

When military bases, national security agencies, federal buildings, healthcare facilities, and leading commercial clients in Washington D.C and across the nation need superior facility support services, we answer the call. We offer a unique combination of government experience and facilities expertise that has helped us earn a position as one of the country’s leading integrated service providers.

Job Summary

EMCOR Government Services, Inc. is seeking an energetic Critical Facilities Technician to serve as a technical resource and leader for DISA Data Centers in Oklahoma City, OK.

The position will help ensure overall availability and reliability to meet or exceed defined service levels of data center operations. The Critical Facilities Technician is responsible for the overall operation of all electrical, mechanical, HVAC and life-safety equipment within the data center. The Critical Facilities Technician will assist in maintaining high reliability and performance while keeping operating costs in facilities at a minimum. This equipment supports mission-critical servers and must maintain better than 99.999% uptime.

The Critical Facilities Technician is a front line technical specialist responsible for hands on troubleshooting, operation, and maintenance of mission critical data center infrastructure. This includes electrical systems (generators, UPS, switchgear, PDUs, batteries), mechanical systems (CRAC units, chillers, cooling towers, air handlers, pumps, motors), and supporting systems such as BAS controls and fire suppression.

This role is a 3rd shift opening.

$28-36/hr

Essential Duties & Responsibilities
  • Oversee and maintain critical data center infrastructure to ensure reliability and compliance with performance standards.
  • Support installation, maintenance, and repair of electrical, mechanical, and HVAC systems.
  • Monitor and respond to abnormal conditions across mechanical, electrical, fire/life safety, and control systems.
  • Manage critical power distribution from utility/generator systems through UPS to customer load.
  • Ensure fire/life safety systems—including wet, pre action, clean agent suppression, and detection devices—remain fully operational.
  • Conduct inspection rounds, document deficiencies, and ensure corrections are completed.
  • Assist with O&M tasks, facility improvements, and IDIQ project execution.
  • Coordinate with third party vendors; ensure SLA compliance and completion of PM activities.
  • Complete work orders and ensure deliverables align with contract requirements.
  • Participate in after hours on call rotation and lead system recovery efforts when issues arise.
  • Collaborate closely with the Facility Project Manager and Deputy Project Manager.
  • Comply with all PPE and safety requirements.
  • Regular, predictable attendance is essential to satisfactory performance.
  • Perform other duties as assigned.
Qualifications
  • Strong understanding of data-center electrical, mechanical, and fire/life safety systems.
  • Must have at least three years of experience working in a data center or similar mission-critical environment.
  • Familiarity with generators, transformers, switchgear, UPS, ATS/STS, PDUs, CRAC/CRAH units, chilled water systems, and clean agent suppression.
  • Knowledge of NFPA 70E, OSHA safety standards, lockout/tagout, and arc flash protection.
  • Ability to interpret technical drawings, schematics, and system diagrams.
  • Skilled in using critical monitoring systems, trending data, and troubleshooting industrial equipment (chillers, cooling towers, pumps, VFDs, BAS/PLC, HVAC equipment).
  • Proficiency with MS Office and CMMS applications.
  • Strong communication skills and ability to work in a fast paced, high stress environment.
  • Ability to use hand tools, power tools, and electrical test equipment (multimeter, IR camera).
  • Must be willing to work nights, weekends, and holidays as needed.
  • Must work onsite; telework is not permitted.
  • Must possess a valid state issued driver’s license.
  • Must be a U.S. Citizen and currently have, or be able to obtain, a Secret Security Clearance.
Licensing Requirements
  • Must possess an active State of Oklahoma (or reciprocal) Journeyman Electrician License or Journeyman HVAC Mechanical License.
  • Equivalent state recognized journeyman credentials are acceptable based on Oklahoma reciprocity rules.
Education & Certifications
  • High School Diploma or GED required.
  • OSHA‑10 and NFPA 70E certification required during employment.
  • CPR/First Aid certification may be required depending on experience level.
Physical Demands
  • Data center environment with varying temperatures, confined spaces, and high noise levels.
Equal Opportunity Employer

As a leading provider of mechanicaland electrical construction, facilities services, and energy infrastructure,we offer employess a competitive salary and benefits package and we are always looking for individuals with the talent and skills required to contribute to our continued growth and sucess. Equal Oppurtunity Employer/Veterans/Disabled.

Affirmative Action Policy

Please review our Affi…? Wait.

Geographic Disclosure

$28-36/hr

Get your free, confidential resume review.

or drag and drop your file here.

Similar jobs

Similar jobs worth comparing

Critical Facilities Technician (DISA OKC) 2PM to 10:30 PM
Critical Facilities Technician (DISA OKC) 2PM to 10:30 PM

EMCOR Government Services, Inc. • Oklahoma City (OK)

On-site
USD 39,000 - 50,000
Critical Facilities Technician (DISA OKC) 10PM - 6:30AM
Critical Facilities Technician (DISA OKC) 10PM - 6:30AM

EMCOR Government Services, Inc. • Oklahoma City (OK)

On-site
USD 58,000 - 75,000
Critical Facilities Technician (DISA OKC) 10PM - 6:30AM
Critical Facilities Technician (DISA OKC) 10PM - 6:30AM

Redmaneq • Oklahoma City (OK)

On-site
USD 39,000 - 50,000
Critical Facilities Technician (DISA OKC) 2PM to 10:30 PM
Critical Facilities Technician (DISA OKC) 2PM to 10:30 PM

EMCOR Government Services • Oklahoma City (OK)

On-site
USD 39,000 - 50,000
Equal Opportunity Employer
Facilities Technician
Facilities Technician

Insight Global • Oklahoma City (OK)

On-site
USD 55,000 - 75,000
Data Center Critical Facilities Tech (3rd Shift)
Data Center Critical Facilities Tech (3rd Shift)

EMCOR Government Services • Oklahoma City (OK)

On-site
USD 39,000 - 50,000
Night Shift Critical Facilities Technician — Data Center
Night Shift Critical Facilities Technician — Data Center

Redmaneq • Oklahoma City (OK)

On-site
USD 39,000 - 50,000
Night Shift Critical Facilities Technician
Night Shift Critical Facilities Technician

EMCOR Government Services, Inc. • Oklahoma City (OK)

On-site
USD 58,000 - 75,000
Critical Data Center Technician - 2nd Shift (Onsite)
Critical Data Center Technician - 2nd Shift (Onsite)

EMCOR Government Services • Oklahoma City (OK)

On-site
USD 39,000 - 50,000
Equal Opportunity Employer
Mission-Critical Data Center Technician (2nd Shift)
Mission-Critical Data Center Technician (2nd Shift)

EMCOR Government Services, Inc. • Oklahoma City (OK)

On-site
USD 39,000 - 50,000