Neurophysiology Tech Spec (NR)

capitalhealth

United States

On-site

USD 40,000 - 51,000

Full time

6 days ago
Be an early applicant

Get more replies from employers

Send a job-specific resume in minutes.

Job summary

Capital Health is seeking a technologist to support EEG studies, attach scalp electrodes using the 10/20 system, and ensure patient safety during procedures. The role involves generating clear technical reports for physicians, transferring studies to reader stations, and logging study charges in the department system.

Responsibilities include maintaining electrode impedance under 3 k-Ohms, performing montages, and ensuring proper cleaning and maintenance of recording equipment.

Qualifications

  • Experience with EEG testing and electrode placement.
  • Knowledge of the 10/20 international electrode placement system.
  • Ability to document patient history and study charges accurately.
  • Familiarity with infection control and equipment cleaning.

Responsibilities

  • Verifies patient identity and physician orders for procedures.
  • Measures head and attaches electrodes using the 10/20 system.
  • Ensures patient safety and secures equipment during transport.
  • Prepares technical reports for interpreting physicians.
  • Transfers studies to the reader station and logs charges.
  • Maintains electrode impedance under 3 k-Ohms.
  • Obtains VEP, BAER, SSEP and ATC waveforms.
  • Performs necessary montages and activation procedures.
  • Ventures safety and cleanliness of recording equipment.
  • Maintains sufficient disk space for video EEG data.

Skills

EEG testing
Electrode placement
Patient safety
Medical documentation
Bio-calibration

Tools

Impedance testing devices

Job description

Capital Health is the region's leader in providing progressive, quality patient care with significant investments in our exceptional physicians, nurses and staff, as well as advanced technology. Capital Health is a dynamic health care resource accredited by the DNV that includes two hospitals, an outpatient center, satellite ED, and an expansive network of primary and specialty care. Capital Health Medical Group is made up of more than 600 physicians and other providers who offer primary and specialty care, as well as hospital-based services, to patients throughout the region.

Capital Health recognizes that attracting the best talent is key to our strategy and success as an organization. As a result, we aim for flexibility in structuring competitive compensation offers to ensure we can attract the best candidates.

Pay Range:

$28.70 - $37.32

Scheduled Weekly Hours:

40

Position Overview
  • Verifies identity of the patient using appropriate identifiers and verifies physician order for procedure. Measures the patient's head and attaches electrodes in accordance with the 10/20 international electrode placement system as evidenced by manager observations. Tests functional integrity of electrodes and assures acceptable electrode impedances.
  • Obtains a complete and relevant patient history to include medications as evidenced by departmental documentation tools. Observes all patient safety measures, assuring side-rails on stretchers are upright and locked, except when transferring the patient, all wheelchair and stretcher wheels are locked and patients are under direct supervision by staff at all times as evidenced by manager observation and safety protocols.
  • Removes all electrolyte/gel/collodian and cleans patient's scalp safely and thoroughly at the end of the testing. Logs and submits charges for all studies immediately upon completion in accordance with department policy and procedure. Utilizes appropriate infection control measures to ensure thorough cleansing of electrodes and other recording accessories as evidenced by equipment inspection.
  • Prepares and provides an accurate technical report for the interpreting physician on all studies completed. Performs bio-calibration before and after each EEG study and records all montages in accordance with department policy and procedure as evidenced by the recordings. Performs applicable activation procedures and additional or special investigative montages as directed and/or in accordance with department policy and procedure.
  • Transfers all studies upon completion via the network connection from the collection units (EEG, Ambulatory Reader) to the reader station and verifies transfer in accordance with department policy and procedure. Logs and submits charges on all completed studies immediately upon completion in accordance with department policy and procedure as evidenced by reporting systems.
  • Measures accurately scalp and applicable electrode sites and applies all necessary recording electrodes to obtain a VEP, BAER, SSEP and ATC and ensures acceptable impedance under 3 K-Ohms. Obtains interpretable, replicable waveforms for a VEP, BAER, SSEP and ATC. Obtains additional or prolonged sampling in order to obtain desired outcome.
  • Superimposes accurately all applicable recorded waveforms and measures/tags all replicable peaks in order to obtain absolute and interpeak latencies. Completes accurately and consistently all prerequisite test screening procedures prior to initiating examination as evidenced by documentation of visual acuity for VEP, auditory thresholds for BAEP and obtaining a visible thumb or toe twitch for SSEPs.
  • Logs and submits charges on all completed studies immediately upon completion in accordance with departmental policy and procedure as evidenced by reporting systems. Cleans safely and thoroughly all electrolyte from the patients skin surface and/or scalp. Ensures safe and thorough cleaning of all recording apparatus, including electrodes in accordance with department policy and procedure as evidenced by manager observation.
  • Obtains a complete and relevant patient history to include medications, seizure history, frequency, auras or prodromes, family history and an accurate description of events as described by a caregiver, family member, the patient or physician.
  • Measures the patient’s head and attaches electrodes in accordance with the 10/20 international electrode placement system as evidenced by manager observations. Tests functional integrity of electrodes and assures acceptable electrode impedances. Obtains appropriate electrode impedances and baseline EEG data as evidenced by impedance check and quality of EEG recording.
  • Ensures adequate disk space for five or more days of continuous recorded video EEG and ensures spike detection software is activa
Get your free, confidential resume review.
or drag and drop your file here.
Similar jobs

Similar jobs worth comparing

Neurophysiology Tech: EEG & Brainwave Specialist
Neurophysiology Tech: EEG & Brainwave Specialist

capitalhealth • United States

On-site
USD 40,000 - 51,000
EEG Technician 1 - Lake Main Campus
EEG Technician 1 - Lake Main Campus

Franciscan Missionaries of Our Lady Health System Inc • Baton Rouge (LA)

On-site
USD 40,000 - 60,000
EEG Technologist II
EEG Technologist II

Neuro Pathway • Milwaukee (WI)

On-site
USD 40,000 - 60,000
EEG Technician PRN
EEG Technician PRN

Northwest Healthcare • Tucson (AZ)

Hybrid
USD 45,000 - 55,000
Medical, Dental, and Vision plans
401(k) with Employer Match
Educational Support and Student Loan Repayment
EEG Tech - PRN
EEG Tech - PRN

Advocate Health Care • Libertyville (IL)

On-site
USD 50,000 - 70,000
EEG Tech PRN
EEG Tech PRN

St. Joseph Regional Medical Center • Lewiston (ID)

On-site
USD 50,000 - 65,000
EEG Tech
EEG Tech

Integrated Medical Services (IMS) • Phoenix (AZ)

On-site
USD 50,000 - 64,000
EEG Tech-Neurology
EEG Tech-Neurology

Eisenhower Health • Rancho Mirage (CA)

On-site
EEG Technician
EEG Technician

Memorial Health • Decatur (IL)

On-site
USD 35,000 - 55,000
EEG Technician PRN
EEG Technician PRN

Northwest Medical Center Tucson • Tucson (AZ)

On-site
USD 40,000 - 65,000
Medical, Dental, and Vision plans
PTO and Sick Time
401(k) with Employer Match
+3