Data Center Substation, Protection & Automation Engineer

Alex Loftus

Friendly (MD)

Hybrid

USD 320,000 - 405,000

Full time

4 days ago
Be an early applicant

A complete application in a minute

Tailored resume and cover letter, ready to send.

Get past ATS filters

Job summary

Anthropic Limited seeks a Data Center Substation, Protection & Automation Engineer to own the protection architecture across its US portfolio, from POI to LV switchgear. You will develop and maintain protection philosophy, reference relay settings, and EPMS integration for real-time visibility and secure operation.

You’ll lead protection design, relay settings, and studies, collaborating with partners, vendors, and utility groups.

Qualifications

  • Bachelor's degree in Electrical Engineering or related field; PE licensure valued but not required.
  • 10+ years of experience in power system protection engineering, substation automation, or design for utility/industrial facilities.
  • Deep expertise applying and setting protective relays for transformers, feeders, buses, generators, and switchgear; fluent in major relay platforms.
  • Experience with protection & control for substation automation and SCADA systems; familiarity with IEC 61850, DNP3/Modbus.
  • Ability to review and create protection studies (short-circuit, coordination, arc-flash) and guide equipment selection.

Responsibilities

  • Own protection philosophy and design basis across HV/MV/LV system; maintain relay settings templates.
  • Specify protective relays and settings for transformers, feeders, bus, generator, motor, and arc-flash protection.
  • Perform and review short-circuit, coordination and arc-flash studies; influence equipment selection and energy-mitigation decisions.
  • Implement transfer schemes, load-shed and restoration logic in protection/automation.
  • Review design packages and drive deviations to basis of design; ensure compatibility with standards.

Skills

Power system protection
Substation automation
Relay coordination
IEC 61850
DNP3/Modbus
Project leadership

Education

Bachelor's degree in Electrical Engineering

Tools

SKM
ETAP
CAPEs/ASPEN
GE EnerVista
Siemens DIGSI

Job description

Data Center Substation, Protection & Automation Engineer

Remote-Friendly, United States

About Anthropic

Anthropic’s mission is to create reliable, interpretable, and steerable AI systems. We want AI to be safe and beneficial for our users and for society as a whole. Our team is a quickly growing group of committed researchers, engineers, policy experts, and business leaders working together to build beneficial AI systems.

About the role

Training and serving frontier AI models requires compute infrastructure at a scale and density that pushes past what conventional data center designs were built to handle. Anthropic's Data Center Infrastructure team is responsible for delivering that physical infrastructure — partnering with build partners, equipment manufacturers, and utilities to stand up facilities that can reliably power some of the largest accelerator clusters in the industry. At the scale we build, our campuses are typically served by dedicated high-voltage substations and a medium-voltage distribution network that may also integrate on-site generation and battery energy storage — and the protection, control, and automation layer is what keeps all of it selective, coordinated, and observable.

As a Data Center Substation, Protection & Automation Engineer, you'll own the protection and automation architecture across Anthropic's US portfolio — from the utility point of interconnection (POI) through the HV/MV substation, the MV distribution loop, and down into LV switchgear. You'll develop and maintain our protection philosophy and reference relay settings, run and review the short-circuit, coordination, and arc-flash studies that underpin them, design the substation automation and SCADA architecture, and define how relays and meters integrate into the electrical power monitoring system (EPMS) — giving operators real-time visibility and sequence-of-events data when something trips. You'll also be our technical lead on the protection side of utility interconnection — working relay settings, transfer-trip, and ride-through requirements with transmission owners and ISOs/RTOs.

Protection engineering and substation automation are the core of this role; substation physical design is a strong plus but not a prerequisite — we'd like to hear from protection and P&C engineers who have spent their careers on relays, schemes, and studies even if they haven't owned a substation general arrangement. You'll work closely with colleagues across the infrastructure team, our build partners' A/E firms, relay and switchgear vendors, and utility protection groups. Expect roughly 20–35% travel for witnessing factory acceptance and relay testing, and supporting site energization and commissioning.

Responsibilities
  • Own Anthropic's protection philosophy and basis of design across the electrical system — HV substation, MV distribution, generator and energy-storage interties, and LV switchgear — and maintain the reference relay settings and protection one-line templates our build partners design against
  • Specify protective relays and develop relay settings for transformer, feeder, bus, generator, motor, and arc-flash protection applications, working across major platforms (e.g., SEL, GE Multilin, ABB, Siemens, Schneider)
  • Perform and critically review short-circuit, protective-device coordination, and arc-flash studies; use findings to steer equipment selection, settings, and incident-energy mitigation
  • Implement automatic transfer, load-shed, and restoration schemes in protection and automation logic, and make sure they stay secure and coordinated under every credible contingency
  • Review protection and control design packages, relay settings calculations, and coordination studies from build partners and A/E firms against our basis of design, and drive closure on deviations and exceptions
  • Design the substation automation architecture for each site — IEC 61850 station and process bus, GOOSE messaging, RTUs/gateways, local HMI, sequence-of-events recording, and time synchronization — and drive standardization of that architecture across the portfolio
  • Integrate protective relays, meters, and switchgear controls into the electrical power monitoring system (EPMS) and substation SCADA; define electrical points lists and event/waveform capture, applying the site alarm and HMI standards
  • Help define the network topology, redundancy, and cybersecurity boundaries between substation automation, EPMS, and the facility BMS/DCIM layer, and how protection events surface to operations
  • Evaluate and qualify relay, RTU, gateway, and EPMS platforms on technical merit, and work with supply chain to build a diversified vendor base that mitigates lead-time and single-source risk
Substation design & utility interface
  • Review HV/MV substation design packages from build partners — single-line and three-line diagrams, bus configuration, general arrangement, equipment specifications, grounding-grid design, and control-building layout — and confirm the protection and control design is buildable and maintainable
  • Work with local utilities, transmission owners, and ISOs/RTOs on interconnection protection requirements — relay settings submittals, transfer-trip and communications-assisted schemes, POI study review, and protection settings that satisfy ride-through and grid-code requirements
  • Review the protection and control interface for on-site generation and battery energy storage interconnections, including anti-islanding, synchronizing, and intertie protection
  • Support NERC PRC compliance for applicable facilities — settings documentation, misoperation analysis, and periodic maintenance and testing basis
  • Develop relay test plans and factory and site acceptance test procedures for protection and automation systems, and witness FAT, relay secondary-injection testing, GOOSE messaging and end-to-end scheme testing, and integrated systems testing
  • Review the protection and control steps of energization and switching methods of procedure (MOPs), support first-energization of substations and MV distribution, and resolve protection and control issues found in the field
  • Lead root-cause analysis of protection operations and misoperations using relay event records, sequence-of-events data, and disturbance records, and feed findings back into settings and standards
  • Build and continuously improve Anthropic's internal protection and automation standards — settings templates, scheme logic libraries, test procedures, and commissioning checklists — so each new site starts from a proven baseline
You may be a good fit if you
  • Have 10+ years of experience in power system protection engineering, substation automation, or substation design for utility, heavy-industrial, or mission-critical facilities
  • Hold a bachelor's degree in Electrical Engineering or a closely related field, or have equivalent practical experience; Professional Engineer (PE) licensure is valued but not required
  • Have deep, hands-on expertise applying and setting protective relays for transformers, feeders, buses, generators, and switchgear, and are fluent in at least one major relay platform (e.g., SEL, GE Multilin, ABB, Siemens)
  • Are fluent in short-circuit, protective-device coordination, and arc-flash analysis and comfortable running or critically reviewing studies in tools such as SKM, ETAP, EasyPower, ASPEN, or CAPE
  • Have hands-on experience integrating protective relays into substation automation or SCADA systems using protocols such as DNP3, Modbus, or IEC 61850, and understand RTU/gateway and sequence-of-events architecture
  • Have worked on utility interconnection protection — relay settings submittals, transfer-trip or communications-assisted schemes, or point-of-interconnection protection requirements — from either the utility or the customer side
  • Can read, interpret, and mark up single-line and three-line diagrams, AC and DC schematics, relay panel drawings, and wiring diagrams with confidence
  • Have developed relay test plans and witnessed factory acceptance testing, secondary-injection testing, or field commissioning of protection and control systems
  • Are familiar with the codes and standards that govern protection and substation work — such as the IEEE C37 series, IEEE 1584, NFPA 70/70E, and (for utility-connected or bulk-electric-system facilities) NERC PRC reliability standards
  • Communicate clearly with both technical peers and non-specialist stakeholders, and are results-oriented, with a bias toward practical solutions and a willingness to pick up work outside your core remit when the team needs it
Strong candidates may also have
  • HV/MV substation physical design experience — general arrangement, bus configuration, power transformer and HV breaker specification, grounding-grid design per IEEE 80, insulation coordination, and control-building layout
  • Experience with protection and control for on-site generation (gas turbines, reciprocating engines, fuel cells) and battery energy storage systems, including anti-islanding, synchronizing, and microgrid transfer schemes
  • Background in data center, hyperscaler, or other high-availability electrical distribution, and familiarity with critical-power topologies (2N, N+1, distributed redundant)
  • Experience owning NERC PRC compliance evidence for a generation or transmission asset — settings basis documentation, misoperation reporting, and PRC-005 maintenance programs
  • Proficiency with vendor relay engineering tools such as SEL AcSELerator, GE EnerVista, ABB PCM600, or Siemens DIGSI, and with IEC 61850 system configuration tools
  • Designed IEC 61850 station- or process-bus systems with GOOSE-based protection or interlocking schemes
  • Prior work at a utility, relay or switchgear manufacturer, protection-engineering consultancy, or hyperscaler serving large-load interconnections

For sales roles, the range provided is the role’s On Target Earnings ("OTE") range, meaning that the range includes both the sales commissions/sales bonuses target and annual base salary for the role.

$320,000 - $405,000 USD

Logistics
  • Minimum education: Bachelor’s degree or an equivalent combination of education, training, and/or experience
  • Required field of study: A field relevant to the role as demonstrated through coursework, training, or professional experience
  • Minimum years of experience: Years of experience required will correlate with the internal job level requirements for the position
  • Location-based hybrid policy: Currently, we expect all staff to be in one of our offices at least 25% of the time. However, some roles may require more time in our offices.
  • Visa sponsorship: We do sponsor visas! However, we aren't able to successfully sponsor visas for every role and every candidate. But if we make you an offer, we will make every reasonable effort to get you a visa, and we retain an immigration lawyer to help with this.
How we're different

We believe that the highest-impact AI research will be big science. At Anthropic we work as a single cohesive team on just a few large-scale research efforts. And we value impact — advancing our long-term goals of steerable, trustworthy AI — rather than work on smaller and more specific puzzles. We view AI research as an empirical science, which has as much in common with physics and biology as with traditional efforts in computer science. We're an extremely collaborative group, and we host frequent research discussions to ensure that we are pursuing the highest-impact work at any given time. As such, we greatly value communication skills.

The easiest way to understand our research directions is to read our recent research. This research continues many of the directions our team worked on prior to Anthropic, including: GPT-3, Circuit-Based Interpretability, Multimodal Neurons, Scaling Laws, AI & Compute, Concrete Problems in AI Safety, and Learning from Human Preferences.

Come work with us!

Anthropic is a public benefit corporation headquartered in San Francisco. We offer competitive compensation and benefits, optional equity donation matching, generous vacation and parental leave, flexible working hours, and a lovely office space in which to collaborate with colleagues. Guidance on Candidates' AI Usage: Learn about our policy for using AI in our application process.

Get your free, confidential resume review.

or drag and drop your file here.

Similar jobs

Similar jobs worth comparing

Data Center Substation, Protection & Automation Engineer
Data Center Substation, Protection & Automation Engineer

Anthropic • United States

On-site
USD 320,000 - 405,000
Data Center Substation, Protection & Automation Engineer
Data Center Substation, Protection & Automation Engineer

Zekai • United States

Remote
USD 320,000 - 405,000
Remote role in the United States
Competitive compensation
Equity donation matching
+1
Staff / Senior Physical Security Systems Engineer
Staff / Senior Physical Security Systems Engineer

Anthropic • San Francisco (CA)

On-site
USD 320,000 - 405,000
Senior Field Engineer, Data Center Design and Engineering
Senior Field Engineer, Data Center Design and Engineering

Candidate • San Francisco (CA)

Hybrid
USD 320,000 - 405,000
Competitive compensation
Equity donation matching (optional)
Generous vacation
+3
Data Center Power Generation and Microgrids Engineer
Data Center Power Generation and Microgrids Engineer

Anthropic • United States

Hybrid
USD 320,000 - 405,000
Competitive compensation
Equity donation matching
Generous vacation and parental leave
+1
Data Center Mechanical Engineer
Data Center Mechanical Engineer

Anthropic • United States

On-site
USD 320,000 - 405,000
Data Center Engineer, Reliability & Infrastructure Management – Compute Supply
Data Center Engineer, Reliability & Infrastructure Management – Compute Supply

Anthropic • San Francisco (CA)

Hybrid
USD 320,000 - 405,000
Data Center Engineer, Reliability & Infrastructure Management – Compute Supply
Data Center Engineer, Reliability & Infrastructure Management – Compute Supply

Anthropic • New York (NY)

On-site
USD 320,000 - 405,000
Senior Field Engineer, Data Center Design and Engineering
Senior Field Engineer, Data Center Design and Engineering

AlphaSense • United States

Hybrid
USD 320,000 - 405,000
Senior Field Engineer, Data Center Design and Engineering
Senior Field Engineer, Data Center Design and Engineering

PromptCube • United States

Hybrid
USD 320,000 - 405,000