Data Center Infrastructure - Solutions Mechanical Architect - Plano, TX or Fremont, CA

Delta Electronics Americas

Plano (TX)

On-site

USD 150,000 - 210,000

Full time

8 days ago

Get more replies from employers

Send a job-specific resume in minutes.

Job summary

Delta Electronics Americas invites an experienced Data Center Infrastructure Mechanical Architect to design, validate, and optimize mechanical systems for high-density compute environments. This customer-facing role bridges requirements with product development, emphasizing liquid-cooling technologies and scalable cooling architectures.

You will collaborate across hardware, electrical, and controls teams, develop layouts and piping, model performance, and support installation and commissioning

Qualifications

  • Bachelor’s or Master’s degree in Mechanical Engineering or related field.
  • 7+ years of data-center mechanical design experience.
  • Hands-on experience with dry coolers, evaporative coolers, cooling skids, hydronic systems, and liquid-cooling infrastructure.
  • Strong understanding of heat transfer, thermodynamics, pump curves, and fluid dynamics.
  • Experience collaborating with product development or hardware engineering teams.
  • Excellent communication skills for customer-facing roles.

Responsibilities

  • Act as the primary mechanical engineering interface for customers, gathering requirements and translating needs into specifications.
  • Lead technical discussions with end users, integrators, and partners to ensure designs meet expectations and scalability.
  • Provide guidance on liquid-cooling strategies and deployment best practices.
  • Partner with hardware, electrical, controls, and product engineering teams to influence cooling product designs.
  • Develop mechanical layouts, piping schematics, and system interfaces for new builds and retrofits.
  • Validate system performance through modeling, simulation, and on-site testing.
  • Support customers and field teams during installation, commissioning, and troubleshooting.
  • Create and maintain documentation including standards and commissioning plans.
  • Evaluate site conditions and climate considerations to ensure optimal cooling.
  • Drive optimization for efficiency and reliability; lead root-cause analysis.

Skills

Data-center mechanical design
Thermal management
Hydronic systems
Liquid-cooling infrastructure
Heat transfer & thermodynamics
Cross-functional collaboration
Customer engagement

Education

Bachelor’s or Master’s in Mechanical Engineering

Job description

Delta Electronics is a global innovator at the forefront of technologies powering the future. Since 1971, we’ve been leading the way in high-efficiency power and thermal management solutions. Today, we’re driving transformation across industries with smart, sustainable systems that enable everything from AI, industrial automation, and data centers to EV charging, renewable energy, and intelligent buildings.

Delta is powering the AI age with cutting-edge infrastructure solutions for hyperscale and edge data centers. Our high-efficiency power systems, thermal management, and intelligent monitoring technologies help the world’s largest data operators achieve peak performance and sustainability. Join us to help build the cornerstone solutions that will run tomorrow’s digital world.

Impact of the Role

This architect ensures that customer needs directly shape the evolution of mechanical and cooling technologies, enabling reliable, efficient, and scalable data‑center environments. The role bridges the gap between customer requirements and product innovation, ensuring that cooling infrastructure and hardware designs work together seamlessly.

Key Responsibilities

The Data Center Infrastructure Mechanical Architect serves as a technical leader responsible for designing, validating, and optimizing mechanical systems that support high‑density compute environments. This role is uniquely customer‑facing and works closely with internal product development teams to influence both existing and next‑generation cooling solutions. The ideal candidate brings deep expertise in liquid‑cooling technologies—including dry coolers, evaporative coolers, cooling skids, and hydronic infrastructure—and excels at translating customer needs into scalable, reliable mechanical architectures.

Customer Engagement & Solution Architecture
  • Act as the primary mechanical engineering interface for customers, gathering requirements, understanding deployment constraints, and translating needs into actionable design specifications
  • Lead technical discussions with end users, integrators, and partners to ensure mechanical designs align with operational expectations and long‑term scalability
  • Provide expert guidance on liquid‑cooling strategies, system tradeoffs, and deployment best practices
Cross‑Functional Collaboration with Product Development
  • Partner closely with hardware, electrical, controls, and product engineering teams to influence the design of new cooling products and enhancements to existing offerings
  • Contribute mechanical expertise to product roadmaps, design reviews, and prototype evaluations
  • Ensure new product designs integrate seamlessly with facility‑level cooling infrastructure and meet customer performance requirements
Mechanical System Design & Integration
  • Architect end‑to‑end liquid‑cooling systems, including dry coolers, evaporative coolers, cooling towers, skids, pumps, heat exchangers, filtration systems, and hydronic distribution
  • Develop detailed mechanical layouts, piping schematics, and system interfaces for both new builds and retrofits
  • Validate system performance through modeling, simulation, and on‑site testing
Infrastructure Planning & Deployment Support
  • Support customers and field teams during installation, commissioning, and troubleshooting of liquid‑cooling systems
  • Create and maintain documentation including design standards, sequence‑of‑operations, commissioning plans, and integration guides
  • Evaluate site conditions, climate considerations, and operational constraints to ensure optimal cooling performance
Performance, Reliability & Continuous Improvement
  • Analyze system data to optimize efficiency, reliability, and water/power usage.
  • Identify opportunities for mechanical improvements in both facility infrastructure and product designs
  • Drive root‑cause analysis for mechanical issues and collaborate with development teams to implement corrective actions
Minimum Qualifications
  • Bachelor’s or Master’s degree in Mechanical Engineering or related field.
  • 7+ years of experience in data‑center mechanical design, mission‑critical facilities, or advanced cooling systems
  • Hands‑on experience with dry coolers, evaporative coolers, cooling skids, hydronic systems, and liquid‑cooling infrastructure
  • Strong understanding of heat transfer, thermodynamics, pump curves, and fluid dynamics
  • Experience collaborating with product development or hardware engineering teams
  • Excellent communication skills with the ability to engage directly with customers and translate technical concepts clearly
Pay Range

USD $150,000.00 - USD $210,000.00 /Yr.

Preferred Qualifications
  • Experience supporting AI/ML, HPC, or other high‑density compute environments
  • Familiarity with immersion cooling, direct‑to‑chip cooling, or rear‑door heat exchangers
  • Knowledge of water treatment, filtration, and corrosion‑control strategies.
  • Professional Engineering (PE) license or equivalent experience
Benefit at Delta Electronics Americas

https://www.delta-americas.com/en-US/career/Life-at-Delta

EEO Statement

Delta Electronics Americas is an Equal Opportunity Employer and is committed to compliance with all applicable federal, state, and local laws. Delta Electronics America is committed to fostering a diverse, inclusive, and respectful workplace. All qualified applicants will receive consideration for employment without regard to race, color, religion, sex, sexual orientation, gender identity or expression, age, marital status, national origin, disability, veteran status, or any other protected characteristic.

Get your free, confidential resume review.
or drag and drop your file here.
Similar jobs

Similar jobs worth comparing

Data Center Infrastructure - Solutions Mechanical Architect - Fremont, CA or Plano, TX
Data Center Infrastructure - Solutions Mechanical Architect - Fremont, CA or Plano, TX

Delta Electronics Americas • Fremont (CA)

On-site
USD 150,000 - 210,000
Data Center Infrastructure – Solutions Mechanical Architect
Data Center Infrastructure – Solutions Mechanical Architect

Delta Electronics Americas • Fremont (CA)

On-site
USD 120,000 - 180,000
Senior Mechanical Engineer – Data Center Solutions & Architecture
Senior Mechanical Engineer – Data Center Solutions & Architecture

Delta Electronics Americas • Plano (TX)

On-site
USD 90,000 - 130,000
Thermal R&D Engineer - Fremont, CA
Thermal R&D Engineer - Fremont, CA

Delta Electronics Americas • Fremont (CA)

On-site
USD 100,000 - 130,000
Diverse and inclusive workplace
Opportunities for professional development
Product Manager - Data Center Cooling
Product Manager - Data Center Cooling

Delta Electronics Americas • Plano (TX)

On-site
USD 95,000 - 130,000
Diverse and inclusive workplace
Commitment to sustainability initiatives
Project Manager Engineer - Liquid Cooling
Project Manager Engineer - Liquid Cooling

Delta Electronics Americas • Plano (TX)

On-site
USD 80,000 - 110,000
Data Center Liquid-Cooling Solutions Architect
Data Center Liquid-Cooling Solutions Architect

Delta Electronics Americas • Plano (TX)

On-site
USD 150,000 - 210,000
Senior Account Manager - Data Center - Fremont
Senior Account Manager - Data Center - Fremont

Delta Electronics Americas • Fremont (CA)

On-site
USD 160,000 - 180,000
Health coverage
Retirement savings plan
Paid time off
+1
Senior Data Center Liquid-Cooling Architect
Senior Data Center Liquid-Cooling Architect

Delta Electronics Americas • Fremont (CA)

On-site
USD 150,000 - 210,000
Senior Field Application Engineer - Thermal/Cooling - Fremont
Senior Field Application Engineer - Thermal/Cooling - Fremont

Delta Electronics Americas • Plano (TX)

On-site
USD 90,000 - 120,000