A complete application in a minute
Tailored resume and cover letter, ready to send.
Private Advertiser in Malaysia is seeking an experienced technician to support the deployment of mission-critical structured cabling and ICT infrastructure for an AI Data Centre project. You will install, terminate, test and troubleshoot copper cabling, racks and patching to project requirements.
The role emphasizes hands-on Cat6/Cat6A installation, cable management, labelling and detailed documentation. You will guide junior technicians and collaborate with QA/QC and supervisors to ensure
Join the project delivery team supporting the deployment of mission-critical structured cabling and ICT infrastructure for an AI Data Centre project in Malaysia. This role will install, terminate, test and troubleshoot copper structured cabling and associated rack and patching infrastructure to project requirements, supporting reliable data centre operations and successful project handover.
Key responsibilities
Install and route specified copper cabling, including Cat6, Cat6A and other approved categories.
Perform cable pulling, dressing, termination and patch panel and outlet installation.
Install and dress racks, cabinets, horizontal and vertical cable managers and patching hardware where in scope.
Apply cable identification and labelling in accordance with the project administration scheme.
Conduct wire-map and certification testing using approved cable test equipment.
Interpret test results, identify failures and rectify termination or installation defects.
Maintain separation, bend radius, pulling tension and manufacturer installation requirements.
Coordinate work with fibre specialists, supervisors and QA/QC inspectors.
Maintain test logs, cable schedules, port records and as-built mark-ups.
Care for tools and test instruments and report calibration or equipment issues.
Guide junior technicians and helpers.
Support inspection, testing, commissioning and handover documentation activities.
What we're looking for
Typically 4–5 years of structured cabling installation experience.
Hands-on experience with Cat6 or Cat6A cabling, patch panels, outlets, racks and cable management.
Experience using Fluke DSX or equivalent certification testers is highly desirable.
Understanding of TIA-568 performance requirements, link testing, permanent link and channel concepts, labelling and rack dressing.
BICSI Installer certification or manufacturer training is an advantage.
Data centre rack cabling experience is preferred.
Strong attention to installation quality, testing accuracy, documentation and project requirements.