Senior BMS Commissioning Engineer - Data Centres

Facility Performance Consulting

Mumbai

Sur place

INR 1 200 000 - 2 000 000

Plein temps

14 jours+
Générateur de candidature

Une candidature complète en une minute — un CV et une lettre de motivation personnalisés, prêts à envoyer.

Passez les filtres ATS

Résumé du poste

FPC Global seeks a Senior BMS Commissioning Engineer (CxA) to provide independent oversight and acceptance of BMS and associated ELV systems across Tier III/IV data centre developments. The role is site-focused, owner/operator representation with emphasis on design intent, reliability, and operational readiness.

You will lead commissioning strategies, witness IST, validate mechanical/ELV integration, and oversee vendor performance, working to ensure seamless integration, fault tolerance, and

Qualifications

  • Degree in Engineering (Mechanical, Electrical, Controls or equivalent).
  • 8-12+ years experience in BMS / controls commissioning.
  • Minimum 5 years in a client-side, CxA, or independent assurance role within data centres or mission-critical facilities.

Responsabilités

  • Act as Commissioning Authority (CxA) for BMS and integrated monitoring systems on owner-operated projects.
  • Define, review and enforce BMS commissioning strategies, acceptance criteria and milestones.
  • Witness and validate IST methodologies, scripts, failure mode testing and fault-tolerance for availability objectives.
  • Independently validate BMS integration with mechanical, electrical, ELV systems and EPMS.
  • Own client-side acceptance of ELV systems including access control, CCTV and fire alarm monitoring.
  • Produce commissioning documentation, handover reports and support operator training.

Connaissances

BMS commissioning
IST execution
Client-side role
Data centre operations
Systems integration
Cybersecurity considerations

Formation

Engineering degree

Outils

AutoCAD
BMS platforms
Visio
Excel

Description du poste

Job Description

FPC Global is seeking a Senior BMS Commissioning Engineer (CxA) to provide independent technical oversight, validation, and acceptance of Building Management Systems (BMS) and associated ELV and environmental risk monitoring systems across Tier III / Tier IV data centre developments.

Acting on behalf of the owner/operator, the role ensures that control systems, monitoring platforms, and automated responses accurately reflect design intent, support operational playbooks, and demonstrate fault tolerance through Integrated Systems Testing (IST).

This is a site-focused, assurance-led role requiring deep technical expertise in controls, systems integration, and mission-critical operations.

Key Responsibilities
Client-Side BMS Commissioning Authority
  • Act as Commissioning Authority (CxA) for BMS and integrated monitoring systems, representing the owner s technical and operational interests.
  • Define, review and enforce BMS commissioning strategies, acceptance criteria and readiness milestones.
Integrated Systems Testing (IST) Assurance
  • Review, challenge and approve BMS-led IST methodologies and scripts in accordance with Uptime Institute Tier Standards.
  • Witness and validate failure mode, redundancy and fault-tolerance testing, ensuring automated responses meet availability objectives.
  • Confirm BMS supports operator situational awareness during degraded and fault conditions.
Mechanical Electrical Integration Validation
  • Independently validate BMS integration with:
    • Mechanical systems (chillers, CRAH/CRAC, AHUs, pumps, valves, heat rejection plant)
    • Electrical systems via EPMS (UPS, generators, switchgear, PDUs, STS)
  • Verify sequences of operation, interlocks, alarms, trending and control logic accuracy.
ELV Systems Acceptance (Client Representation)
  • Own client-side acceptance of ELV systems, including:
    • Access control and security monitoring
    • CCTV and video management interfaces
    • Fire alarm monitoring and supervisory interfaces (where permitted)
    • Network resilience and segregation supporting BMS / ELV platforms
  • Ensure ELV systems are fully integrated, documented and operationally visible.
Leak Detection Systems Assurance
  • Validate commissioning and integration of water leak detection (WLD) systems across white space, plant areas and critical pathways.
  • Confirm zoning, alarm prioritisation, escalation logic and operator response workflows.
  • Witness leak-related IST scenarios and approve system acceptance.
Rodent Detection Environmental Risk Monitoring
  • Act as client authority for rodent detection and environmental risk monitoring systems.
  • Validate sensor coverage, alarm logic, escalation paths and BMS integration.
  • Ensure alignment with hyperscale environmental risk mitigation strategies.
Design Commissionability Reviews
  • Perform independent design reviews of BMS, controls, and ELV architectures at all project stages.
  • Review control philosophies, points lists, network topologies, graphics standards and vendor submittals for operability and resilience.
Vendor Contractor Oversight
  • Provide technical oversight of BMS, controls and ELV vendors without direct installation responsibility.
  • Identify non-conformances, issue technical observations and drive corrective actions to closure prior to acceptance.
Documentation, Acceptance Handover
  • Review and approve commissioning documentation including:
    • Commissioning plans, test procedures, and IST scripts
    • Point-to-point and functional test evidence
    • Configuration baselines and as-built records
    • Final commissioning and acceptance reports
  • Support operator training, handover and transition to steady-state operations.
Compliance Readiness Assurance
  • Ensure alignment with:
    • Uptime Institute Tier Standards (TCCF focus)
    • ASHRAE, IEC, ISO and applicable local codes
    • Client-specific hyperscale standards and operational playbooks
  • Confirm closure of all critical items prior to RFS / RFO milestones.
Qualifications
Qualifications Experience
Essential Qualifications
  • Degree in Engineering (Mechanical, Electrical, Controls, or equivalent).
  • 8-12+ years experience in BMS / controls commissioning.
  • Minimum 5 years in a client-side, CxA, or independent assurance role within data centres or mission-critical facilities.
Technical Expertise
  • Advanced knowledge of:
    • Data centre BMS architectures and hyperscale operating models
    • Integrated mechanical, electrical, and ELV monitoring environments
    • Failure mode testing, IST execution and operational readiness validation
    • Control system resilience, redundancy and cybersecurity considerations
Documentation Reporting
  • Authoring and review of commissioning strategies, acceptance criteria and test scripts.
  • Evaluation of cause-and-effect matrices and control philosophies.
  • Production of formal CxA reports, issue logs and acceptance recommendations.
Tools Platforms
  • Enterprise BMS platforms (Schneider, Siemens, Honeywell, Johnson Controls).
  • EPMS and supervisory monitoring systems.
  • AutoCAD / BIM / Visio.
  • Direct experience supporting Uptime Tier Certification of Constructed Facility (TCCF).
  • Experience with FDD and automated commissioning systems is highly advantageous.

Disclaimer: This job posting has been aggregated from external source. Role details, content, and availability are subject to change. Applicants are advised to confirm the latest information directly on the company website before applying.

Obtenez votre examen gratuit et confidentiel de votre CV.

ou faites glisser et déposez votre fichier ici.

Similar jobs

Postes similaires à comparer

Senior BMS Commissioning Engineer - Data Centres
Senior BMS Commissioning Engineer - Data Centres

FPC Group • Navi Mumbai

Sur place
INR 4 000 000 - 6 000 000
Technical Team Leader - Mechanical Commissioning (CxA)- Datacenter
Technical Team Leader - Mechanical Commissioning (CxA)- Datacenter

Facility Performance Consulting • Mumbai

Sur place
INR 6 000 000 - 12 000 000
Data Centre Commissioning Manager / CxA
Data Centre Commissioning Manager / CxA

Electromech Infraprojects • Mumbai

Sur place
INR 3 200 000 - 5 200 000
Senior BMS Commissioning Engineer - Data Centres
Senior BMS Commissioning Engineer - Data Centres

Facility Performance Consulting Limited • Navi Mumbai

Sur place
INR 2 500 000 - 4 500 000
Data Center Mechanical Commissioning Engineer
Data Center Mechanical Commissioning Engineer

ABL Tech Consultancy • Chennai District

Sur place
INR 2 500 000 - 4 500 000
Datacenter - BMS Commissioning Engineer
Datacenter - BMS Commissioning Engineer

FPC Group • Mumbai

Sur place
INR 1 400 000 - 2 100 000
Sr Mechanical Commissioning Engineer - Data Centres
Sr Mechanical Commissioning Engineer - Data Centres

Facility Performance Consulting • Mumbai

Sur place
INR 1 200 000 - 1 800 000
Professional, Project / Programme Execution
Professional, Project / Programme Execution

JLL • Hyderabad

Sur place
INR 4 200 000 - 6 600 000
Senior Mechanical Commissioning Engineer - Data Centres
Senior Mechanical Commissioning Engineer - Data Centres

Facility Performance Consulting • Mumbai

Sur place
INR 1 800 000 - 3 200 000
Commissioning Manager
Commissioning Manager

Bureau Veritas Mission Critical • Mumbai

Sur place
INR 2 400 000 - 4 200 000