Reliability & Maintenance Engineer, INQC

Amazon Inc.

New Delhi

On-site

INR 600,000 - 900,000

Full time

14 days+

Get a reply from this employer

Your resume and cover letter, tailored to exactly what they’re hiring for.

Get past ATS filters

Job summary

Amazon Inc. in Delhi seeks a skilled Maintenance Engineer to support large-scale refrigeration and base building equipment. You will execute PPM schedules, monitor temperature controls across cold rooms, and coordinate with OEMs for annual maintenance.

The role requires 3–5 years of hands‑on refrigeration experience, proficiency with BMS, DG and UPS systems, and strong RCA/CAPA capabilities. You will compile daily to monthly performance reports and ensure electrical safety compliance.

Qualifications

  • Diploma or bachelor’s degree in mechanical, electrical, or refrigeration & air conditioning.
  • 3–5 years hands‑on experience in refrigeration systems and base building maintenance.
  • Proficiency in refrigeration cycles, electrical systems, DG and UPS, and BMS platforms.
  • Certifications in Refrigeration & Electrical Safety preferred.
  • Analytical skills for RCA, CAPA, and data‑driven decisions.
  • Proficient in technical reporting using MS Excel and related tools.
  • Clear verbal and written communication for cross‑functional coordination.

Responsibilities

  • Execute planned preventive maintenance schedules for refrigeration systems and cold rooms.
  • Monitor temperature parameters across all cold chain zones per SOPs.
  • Inspect compressors, condensers, evaporators, expansion valves, and piping.
  • Maintain refrigerant levels and perform periodic leak tests.
  • Coordinate with OEMs and service providers for repairs and annual maintenance.
  • Diagnose faults including compressor failures and refrigerant leaks.
  • Respond to temperature excursion alarms with defined corrective actions.
  • Troubleshoot faults in refrigeration panels, PLCs, and BMS interfaces.
  • Conduct RCA for recurring failures and implement permanent fixes.
  • Maintain DG sets, fuel systems, batteries, and load bank testing.
  • Maintain UPS systems and perform battery health checks and firmware updates.
  • Monitor electrical panels (MDB, SDB, ATS) and change‑over panels.
  • Perform IR testing, earth resistance tests, and thermography surveys.
  • Ensure electrical safety compliance and safety standards.
  • Prepare daily, weekly, and monthly equipment reports and dashboards.

Skills

Refrigeration systems
Electrical safety
BMS platforms
DG operations
UPS systems
Root cause analysis
CAPA planning
MS Excel
Communication skills

Education

Diploma or B.E./B.Tech in Mechanical/Electrical/Refrigeration & Air Conditioning

Tools

PLC/SCADA/BMS
BMS software

Job description

Description
Key Responsibilities
  1. Execute planned preventive maintenance (PPM) schedules for all refrigeration systems, including tropical rooms, chilled rooms, and frozen rooms.

  2. Monitor and maintain optimal temperature parameters across all cold chain zones in strict accordance with defined Standard Operating Procedures (SOPs).

  3. Conduct routine inspections of compressors, condensers, evaporators, expansion valves, and refrigerant piping systems.

  4. Ensure refrigerant levels are maintained within specified limits and perform periodic leak detection tests.

  5. Monitor and maintain defrost cycles, drain lines, and insulation integrity of all cold rooms.

  6. Coordinate with Original Equipment Manufacturers (OEMs) and third-party service providers for specialized repairs and annual maintenance contracts.

  7. Diagnose and resolve refrigeration system faults, including compressor failures, refrigerant leaks, thermostat malfunctions, and evaporator icing.

  8. Respond to temperature excursion alarms and execute corrective actions within defined response timelines.

  9. Troubleshoot electrical and control system faults in refrigeration panels, PLCs, and Building Management System (BMS) interfaces.

  10. Perform root cause identification for recurring equipment failures and implements verified permanent fixes.

  11. Maintain and monitor Diesel Generator (DG) sets, including fuel systems, coolant levels, battery health, and periodic load bank testing.

  12. Execute preventive and predictive maintenance on Uninterruptible Power Supply (UPS) systems, including battery health checks, load testing, and firmware updates.

  13. Monitor and maintain electrical panels — including Main Distribution Boards (MDB), Sub-Distribution Boards (SDB), Automatic Transfer Switches (ATS), and change-over panels.

  14. Conduct periodic insulation resistance (IR) testing, earth resistance testing, and thermography surveys of all electrical systems.

  15. Ensure full compliance with applicable electrical safety standards and statutory requirements.

  16. Monitor real-time equipment parameters through the BMS, temperature monitoring systems, and energy meters.

  17. Conduct daily walkthroughs to identify abnormalities, unusual sounds, vibrations, or visual defects in equipment.

  18. Track and maintain equipment runtime hours, energy consumption data, and performance trends.

  19. Ensure all monitoring sensors and alarm systems are calibrated and fully functional at all times.

  20. Daily Reports — Prepare and submit daily equipment status reports covering temperature logs, DG runtime, UPS status, and all observed anomalies.

  21. Weekly Reports — Compile weekly maintenance summary reports covering PPM compliance, breakdown analysis, spare parts consumption, and pending work orders.

  22. Monthly Reports — Develop monthly performance reports inclusive of equipment uptime percentage, Mean Time Between Failures (MTBF), Mean Time To Repair (MTTR), energy consumption trends, and cost analysis.

  23. Conduct structured Root Cause Analysis (RCA) for all equipment breakdowns, temperature excursions, and safety incidents using methodologies such as Five-Why Analysis and Fishbone Diagrams.

  24. Develop and implement Corrective and Preventive Actions (CAPA) with clearly defined timelines, responsible owners, and effectiveness verification criteria.

  25. Maintain a CAPA tracker with closure status, evidence of implementation, and effectiveness validation records.

  26. Present RCA and CAPA findings during Weekly Business Reviews (WBR) and Monthly Business Reviews (MBR).

Qualifications & Skills
  • Education — Diploma or bachelor’s degree in mechanical engineering, Electrical Engineering, or Refrigeration & Air Conditioning.
  • Experience — Minimum three to five years of hands‑on experience in refrigeration systems and base building equipment maintenance.
  • Technical Knowledge — Proficiency in refrigeration cycles, electrical systems, DG operations, UPS systems, and BMS platforms.
  • Certifications — Preferred certifications in Refrigeration & Air Conditioning, Electrical Safety, or equivalent recognised standards.
  • Analytical Skills — Ability to perform structured RCA, develop CAPA plans, and apply data‑driven decision‑making.
  • Reporting Skills — Proficiency in preparing technical reports, dashboards, and MIS outputs using MS Excel and relevant tools.
  • Communication — Clear verbal and written communication skills for effective cross‑functional coordination.
Working Conditions
  • Shift‑based operations with rotational shifts as applicable to site requirements.
  • Sustained exposure to cold room environments, including frozen rooms operating at sub‑zero temperatures.
  • Regular work in proximity to live electrical systems — adherence to all safety protocols is mandatory.
  • On‑call availability required for emergency breakdowns and critical temperature excursion response.
Key job responsibilities
  1. Execute planned preventive maintenance (PPM) schedules for all refrigeration systems, including tropical rooms, chilled rooms, and frozen rooms.

  2. Monitor and maintain optimal temperature parameters across all cold chain zones in strict accordance with defined Standard Operating Procedures (SOPs).

  3. Conduct routine inspections of compressors, condensers, evaporators, expansion valves, and refrigerant piping systems.

  4. Ensure refrigerant levels are maintained within specified limits and perform periodic leak detection tests.

  5. Monitor and maintain defrost cycles, drain lines, and insulation integrity of all cold rooms.

  6. Coordinate with Original Equipment Manufacturers (OEMs) and third‑party service providers for specialized repairs and annual maintenance contracts.

  7. Diagnose and resolve refrigeration system faults, including compressor failures, refrigerant leaks, thermostat malfunctions, and evaporator icing.

  8. Respond to temperature excursion alarms and execute corrective actions within defined response timelines.

  9. Troubleshoot electrical and control system faults in refrigeration panels, PLCs, and Building Management System (BMS) interfaces.

  10. Perform root cause identification for recurring equipment failures and implements verified permanent fixes.

  11. Maintain and monitor Diesel Generator (DG) sets, including fuel systems, coolant levels, battery health, and periodic load bank testing.

  12. Execute preventive and predictive maintenance on Uninterruptible Power Supply (UPS) systems, including battery health checks, load testing, and firmware updates.

  13. Monitor and maintain electrical panels — including Main Distribution Boards (MDB), Sub-Distribution Boards (SDB), Automatic Transfer Switches (ATS), and change-over panels.

  14. Conduct periodic insulation resistance (IR) testing, earth resistance testing, and thermography surveys of all electrical systems.

  15. Ensure full compliance with applicable electrical safety standards and statutory requirements.

  16. Monitor real-time equipment parameters through the BMS, temperature monitoring systems, and energy meters.

  17. Conduct daily walkthroughs to identify abnormalities, unusual sounds, vibrations, or visual defects in equipment.

  18. Track and maintain equipment runtime hours, energy consumption data, and performance trends.

  19. Ensure all monitoring sensors and alarm systems are calibrated and fully functional at all times.

  20. Daily Reports — Prepare and submit daily equipment status reports covering temperature logs, DG runtime, UPS status, and all observed anomalies.

  21. Weekly Reports — Compile weekly maintenance summary reports covering PPM compliance, breakdown analysis, spare parts consumption, and pending work orders.

  22. Monthly Reports — Develop monthly performance reports inclusive of equipment uptime percentage, Mean Time Between Failures (MTBF), Mean Time To Repair (MTTR), energy consumption trends, and cost analysis.

  23. Conduct structured Root Cause Analysis (RCA) for all equipment breakdowns, temperature excursions, and safety incidents using methodologies such as Five-Why Analysis and Fishbone Diagrams.

  24. Develop and implement Corrective and Preventive Actions (CAPA) with clearly defined timelines, responsible owners, and effectiveness verification criteria.

  25. Maintain a CAPA tracker with closure status, evidence of implementation, and effectiveness validation records.

  26. Present RCA and CAPA findings during Weekly Business Reviews (WBR) and Monthly Business Reviews (MBR).

Key Responsibilities
  1. Execute planned preventive maintenance (PPM) schedules for all refrigeration systems, including tropical rooms, chilled rooms, and frozen rooms.

  2. Monitor and maintain optimal temperature parameters across all cold chain zones in strict accordance with defined Standard Operating Procedures (SOPs).

  3. Conduct routine inspections of compressors, condensers, evaporators, expansion valves, and refrigerant piping systems.

  4. Ensure refrigerant levels are maintained within specified limits and perform periodic leak detection tests.

  5. Monitor and maintain defrost cycles, drain lines, and insulation integrity of all cold rooms.

  6. Coordinate with Original Equipment Manufacturers (OEMs) and third‑party service providers for specialized repairs and annual maintenance contracts.

  7. Diagnose and resolve refrigeration system faults, including compressor failures, refrigerant leaks, thermostat malfunctions, and evaporator icing.

  8. Respond to temperature excursion alarms and execute corrective actions within defined response timelines.

  9. Troubleshoot electrical and control system faults in refrigeration panels, PLCs, and Building Management System (BMS) interfaces.

  10. Perform root cause identification for recurring equipment failures and implements verified permanent fixes.

  11. Maintain and monitor Diesel Generator (DG) sets, including fuel systems, coolant levels, battery health, and periodic load bank testing.

  12. Execute preventive and predictive maintenance on Uninterruptible Power Supply (UPS) systems, including battery health checks, load testing, and firmware updates.

  13. Monitor and maintain electrical panels — including Main Distribution Boards (MDB), Sub‑Distribution Boards (SDB), Automatic Transfer Switches (ATS), and change‑over panels.

  14. Conduct periodic insulation resistance (IR) testing, earth resistance testing, and thermography surveys of all electrical systems.

  15. Ensure full compliance with applicable electrical safety standards and statutory requirements.

  16. Monitor real‑time equipment parameters through the BMS, temperature monitoring systems, and energy meters.

  17. Conduct daily walkthroughs to identify abnormalities, unusual sounds, vibrations, or visual defects in equipment.

  18. Track and maintain equipment runtime hours, energy consumption data, and performance trends.

  19. Ensure all monitoring sensors and alarm systems are calibrated and fully functional at all times.

  20. Daily Reports — Prepare and submit daily equipment status reports covering temperature logs, DG runtime, UPS status, and all observed anomalies.

  21. Weekly Reports — Compile weekly maintenance summary reports covering PPM compliance, breakdown analysis, spare parts consumption, and pending work orders.

  22. Monthly Reports — Develop monthly performance reports inclusive of equipment uptime percentage, Mean Time Between Failures (MTBF), Mean Time To Repair (MTTR), energy consumption trends, and cost analysis.

  23. Conduct structured Root Cause Analysis (RCA) for all equipment breakdowns, temperature excursions, and safety incidents using methodologies such as Five‑Why Analysis and Fishbone Diagrams.

  24. Develop and implement Corrective and Preventive Actions (CAPA) with clearly defined timelines, responsible owners, and effectiveness verification criteria.

  25. Maintain a CAPA tracker with closure status, evidence of implementation, and effectiveness validation records.

  26. Present RCA and CAPA findings during Weekly Business Reviews (WBR) and Monthly Business Reviews (MBR).

Qualifications & Skills
  • Education — Diploma or bachelor’s degree in mechanical engineering, Electrical Engineering, or Refrigeration & Air Conditioning.
  • Experience — Minimum three to five years of hands‑on experience in refrigeration systems and base building equipment maintenance.
  • Technical Knowledge — Proficiency in refrigeration cycles, electrical systems, DG operations, UPS systems, and BMS platforms.
  • Certifications — Preferred certifications in Refrigeration & Air Conditioning, Electrical Safety, or equivalent recognised standards.
  • Analytical Skills — Ability to perform structured RCA, develop CAPA plans, and apply data‑driven decision‑making.
  • Reporting Skills — Proficiency in preparing technical reports, dashboards, and MIS outputs using MS Excel and relevant tools.
  • Communication — Clear verbal and written communication skills for effective cross‑functional coordination.
Working Conditions
  • Shift‑based operations with rotational shifts as applicable to site requirements.
  • Sustained exposure to cold room environments, including frozen rooms operating at sub‑zero temperatures.
  • Regular work in proximity to live electrical systems — adherence to all safety protocols is mandatory.
  • On‑call availability required for emergency breakdowns and critical temperature excursion response.
Basic Qualifications
  • Experience in Electrical/Mechanical/Electronics and Communication/Instrumentation and Controls

  • Experience in handling Cooling systems/Chiller/Cold storage for minimum 2years

Preferred Qualifications
  • 1+ years of conveyors/automation/control systems maintenance experience

Our inclusive culture empowers Amazonians to deliver the best results for our customers. If you have a disability and need a workplace accommodation or adjustment during the application and hiring process, including support for the interview or onboarding process, please visit https://amazon.jobs/content/en/how-we-hire/accommodations for more information. If the country/region you’re applying in isn’t listed, please contact your Recruiting Partner.

Get your free, confidential resume review.

or drag and drop your file here.

Similar jobs

Similar jobs worth comparing

Reliability & Maintenance Engineer, GSF
Reliability & Maintenance Engineer, GSF

Amazon Inc. • Bengaluru

On-site
INR 900,000 - 1,200,000
Refrigeration Engineer/Program Manager, Global Energy Sustainability & Automation (GESA)
Refrigeration Engineer/Program Manager, Global Energy Sustainability & Automation (GESA)

Amazon Inc. • Hyderabad

On-site
INR 900,000 - 1,500,000
Refrigeration Specialist, Amazon Maintenance Operation Center (RME)
Refrigeration Specialist, Amazon Maintenance Operation Center (RME)

Amazon.com • Hyderabad

On-site
INR 900,000 - 1,300,000
Refrigeration Specialist, Amazon Maintenance Operation Center (RME)
Refrigeration Specialist, Amazon Maintenance Operation Center (RME)

Amazon Inc. • Hyderabad

On-site
INR 1,200,000 - 2,400,000
RME Coordinator, RME
RME Coordinator, RME

Amazon Inc. • Hyderabad

On-site
INR 600,000 - 900,000
Reliability & Maintenance Engineer
Reliability & Maintenance Engineer

Amazon • Ahmedabad

On-site
INR 450,000 - 750,000
Reliability & Maintenance Engineer
Reliability & Maintenance Engineer

Amazon • Surat

On-site
INR 360,000 - 600,000
General Manager- Cold Storages Refrigeration Mentainance
General Manager- Cold Storages Refrigeration Mentainance

Coldman Logistics • Navi Mumbai

On-site
INR 1,800,000 - 3,000,000
Reliability and Maintenance Engineer
Reliability and Maintenance Engineer

Amazon India Limited • Gurugram District

On-site
INR 520,000 - 800,000
Reliability & Maintenance Engineer
Reliability & Maintenance Engineer

Amazon • Jaipur

On-site
INR 250,000 - 350,000