Lead - Testing, Commissioning & Quality (Data Centers)

Adler Talent Solutions Pvt Ltd

Mumbai

On-site

INR 900,000 - 1,500,000

Full time

5 days ago
Be an early applicant

A complete application in a minute

Tailored resume and cover letter, ready to send.

Get past ATS filters

Job summary

Transrail is seeking a seasoned Commissioning Manager to lead Electrical and Mechanical systems commissioning for large data center projects. You will design commissioning strategy, IST protocols, and lead planning from design through handover.

You will manage multidisciplinary teams, coordinate FATs/SATs with OEMs, oversee QA/QC, and drive operational readiness. BE/B.Tech in Electrical or Mechanical with 10–15 years in DC commissioning; 5+ years in DC commissioning and additional certifications

Qualifications

  • BE/B.Tech in Electrical/Mechanical Eng (Mandatory) with 10–15 years of experience.
  • Minimum 5 years in Data Center commissioning.
  • Additional certifications in Data centre Commissioning, Quality or Reliability preferred.
  • Experience with hyperscale or colocation facilities on commissioning and quality assurance.
  • Proven experience in mission-critical infrastructure.

Responsibilities

  • Lead commissioning strategy and IST planning for Data Center projects.
  • Head electrical systems commissioning across substation, UPS, switchgear, gensets, SCADA.
  • Oversee mechanical commissioning of cooling, pumps, water systems, integration with electrical.
  • Develop IST protocols and conduct tests including blackout scenarios.
  • Establish Quality Management Systems and audit readiness.
  • Coordinate with OEMs and vendors for FATs and commissioning.
  • Interface with customers for audits, witness testing and acceptance.
  • Build teams across phases: electrical, mechanical, QA/QC.
  • Develop commissioning SOPs, quality manuals, templates and checklists.

Skills

Leadership
Team management
Quality management
IST development
Customer interface

Education

BE/B.Tech Electrical/Mechanical Engineering

Tools

SCADA

Job description

Role & responsibilities
  • 1. Commissioning Strategy & Leadership
    Establish commissioning philosophy and procedures for all Data Center projects.
    Develop Level 1 to Level 5 commissioning protocols.
    Define Integrated Systems Testing (IST) methodology.
    Lead commissioning planning from design stage through handover.
    Establish Operational Readiness and Day-One readiness processes.
  • 2. Electrical Systems Commissioning
    Lead team of commissioning engineers for : - - - - - - - - - - - -
    400kV / 220kV / 132kV Receiving Stations
    GIS/AIS Substations
    Transformers
    MV Switchgear
    LV Switchgear
    UPS Systems
    Static Transfer Switches
    Busway Systems
    Generator Systems
    Synchronization Systems
    Protection Systems
    SCADA Systems
  • 3. Mechanical Systems Commissioning
    Oversee commissioning of: - - - - - - - -
    Chilled Water Systems
    CRAH Units
    CRAC Units
    Cooling Towers
    Pumps
    Thermal Containment Systems
    Fuel Systems
    Water Treatment Plants
    Ensure proper integration with electrical infrastructure.
  • 4. Integrated Systems Testing (IST) - - - - - - -
    Develop complete IST protocols.
    Validate redundancy architecture.
    Verify failover and recovery sequences.
    Conduct black building tests.
    Conduct utility outage simulations.
    Conduct UPS and generator transition testing.
    Lead customer witness testing.
  • 5. Quality Management
    Establish Quality Management Systems covering: - - - - - - -
    Design Quality Reviews
    Vendor Quality Audits
    FAT Procedures
    SAT Procedures
    Installation Quality
    Documentation Quality
    Handover Quality
    Develop project quality plans and audit systems.
  • 6. OEM & Vendor Coordination
    Coordinate FATs, inspections and commissioning support.
  • 7. Customer Interface
    Represent Transrail during: - - - - -
    Customer audits
    Witness testing
    Technical reviews
    Readiness assessments
    Final acceptance testing
  • 8. Team Building
    Phase 1 - - -
    Electrical Commissioning Manager
    Mechanical Commissioning Manager
    QA/QC Manager
    Phase 2 - -
    IST Specialists
    Documentation Leads
  • 9. Process Development
    Develop: - - - - - -
    Commissioning SOPs
    Quality Manuals
    FAT/SAT Templates
    Inspection Checklists
    Operational Readiness Framework
    Lessons Learned Database
Preferred candidate profile
  • B.E. / B. Tech in Electrical/Mechanical Engineering (Mandatory) with minimum 1015
    years of experience.
  • Minimum 5 years in Data Center commissioning.
  • Additional certifications in Data centre Commissioning, Quality or Reliability preferred.
  • Experience with hyperscale or colocation facilities on commissioning and quality
    assurance.
  • Proven experience in mission-critical infrastructure.
Get your free, confidential resume review.

or drag and drop your file here.

Similar jobs

Similar jobs worth comparing

Technical Team Leader - Electrical Commissioning (CxA)-Datacenter
Technical Team Leader - Electrical Commissioning (CxA)-Datacenter

Facility Performance Consulting • Mumbai

On-site
INR 4,000,000 - 6,000,000
Technical Team Leader - Mechanical Commissioning (CxA)- Datacenter
Technical Team Leader - Mechanical Commissioning (CxA)- Datacenter

Facility Performance Consulting • Mumbai

On-site
INR 6,000,000 - 12,000,000
Data Center Mechanical Commissioning Engineer
Data Center Mechanical Commissioning Engineer

ABL Tech Consultancy • Chennai District

On-site
INR 2,500,000 - 4,500,000
Sr Mechanical Commissioning Engineer - Data Centres
Sr Mechanical Commissioning Engineer - Data Centres

Facility Performance Consulting • Mumbai

On-site
INR 1,200,000 - 1,800,000
Electrical Testing And Commissioning Engineer
Electrical Testing And Commissioning Engineer

Mandavi Devi Gupta • Mumbai

On-site
INR 1,200,000 - 2,400,000
Commissioning -SME
Commissioning -SME

Jones Lang LaSalle Incorporated • Gandhinagar

On-site
INR 3,000,000 - 4,800,000
Lead Electrical - Data Center
Lead Electrical - Data Center

Larsen & Toubro Limited • Chennai District

On-site
INR 500,000 - 800,000
Datacenter - Mechanical Commissioning Engineer
Datacenter - Mechanical Commissioning Engineer

FPC Global • Navi Mumbai

On-site
INR 1,200,000 - 1,800,000
Family Health Insurance
Flexible Holidays
Competitive Salaries and Discretionary Annual Bonus Scheme
+1
Lead Electrical - Data Center
Lead Electrical - Data Center

Larsen & Toubro • Mumbai

On-site
INR 4,000,000 - 6,000,000
Commissioning Manager
Commissioning Manager

Bureau Veritas Mission Critical • Mumbai

On-site
INR 2,400,000 - 4,200,000